English
Language : 

E3JM-R4M4-US Datasheet, PDF (10/13 Pages) Omron Electronics LLC – Built-in Power Supply Photoelectric Sensor
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
E3JM/E3JK
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
E3JM
● Designing
Operation
Note:
The white part of the DIP switch indicates which setting is selected.
Switch
configuration
Switch selection
Timing charts
Models
without
timer
MODE
01
D·ON
L·ON
Operation
selector
MODE
01
D·ON
L·ON
SW1
Models TIMER
with
SW2
timer
Operation
Selector
Selector switch for
timer mode
MODE
01
D·ON
L·ON
MODE
01
D·ON
L·ON
Light-ON, Relay ON,
DC output switching
element ON
Dark-ON, Relay ON
DC output switching
element ON
ON-delay
OFF-delay One-shot delay
ON-delay
MODE
01
MODE
01
MODE
01
D·ON
L·ON D·ON
L·ON D·ON
L·ON
SW1
SW1
SW1
Incident light
TIMER
TIMER
TIMER
No incident light
SW2
SW2
SW2
T
ON
L·ON
Both SW1 and
SW2 at "0."
Only SW2 at "1." Only SW1 at "1,"
OFF
T
which overrides either
setting of SW2.
ON
D·ON
OFF
Note: The operation selector is the same as that for models
without a timer.
Incident light
No incident light
ON
L·ON
OFF
ON
D·ON
OFF
OFF-delay
Incident light
No incident light
T
ON
L·ON
OFF
T
ON
D·ON
OFF
One-shot delay
Incident light
No incident light
T
ON
L·ON
OFF
T
ON
D·ON
OFF
Output Relay Contact
If E3JM/E3JK is connected to a load with contacts that spark when the load is turned OFF (e.g., a contactor or valve), the normally-closed side
may be turned ON before the normally-open side is turned OFF or vice-versa. If both normally-open output and normally-closed output are used
simultaneously, apply an surge suppressor to the load.
Refer to OMRON’s PCB Relays Catalog (X33) for typical examples of surge suppressors.
10