English
Language : 

LM363 Datasheet, PDF (17/22 Pages) National Semiconductor (TI) – LM363 Precision Instrumentation Amplifier
Typical Applications (Continued)
Low Frequency Rolloff (AC Coupling)
1
f1e
e1 Hz
2qC1(50 kX)
f2e100 f1 e 100Hz
Reduced DC voltage gain
attenuates offset error and
1 f noise by a factor of 100
TL H 5609 – 25
Precision Comparator with Balanced Inputs and Variable Offset
Boosted Current Source with Limiting
tpdj15 mS at 1 mV overdrive
DVOUTeV2a0 6V
Hysteresise DVOUT e2 mV
G(R1aR2)
OffseteVSENSE G
g1 3V range
Thermocouple Amplifier with Cold Junction Compensation
R1eR2
IOeGRV2IN
IMAX
e
VBE
R2
j60 mA
TL H 5609 – 26
Input protection circuitry allows
thermocouple to short to 120 VAC without
damaging amplifier
Calibration
1) Apply 50 mV signal in place of thermocouple
Trim R3 for VOUTe12 25V
2) Reconnect thermocouple Trim R9 for correct
output
TL H 5609 – 27
17