English
Language : 

SM8707 Datasheet, PDF (10/20 Pages) Nippon Precision Circuits Inc – Clock Generator with Dual PLLs
SM8707 series
SM8707G
fXTAL = 27.0000MHz, VDD = 3.3V ± 0.3V, VSS = 0V, Ta = – 10 to + 75 °C unless otherwise noted.
Parameter
Symbol
Pins
Condition
Rating
Unit
min
typ
max
External input clock
frequency1
fXTI
XTI
Applies to external clock input use only
–
27.0000
–
MHz
MO1
CL = 40 pF, transition between VOL =
0.2VDD and VOH = 0.8VDD
–
2.0
–
Output clock rise time2
tr
SO3
CL = 25 pF, transition between VOL =
0.2VDD and VOH = 0.8VDD
–
2.0
–
ns
SO1, SO2
CL = 15pF, transition between VOL =
0.2VDD and VOH = 0.8VDD
–
2.0
–
MO1
CL = 40pF, transition between VOH =
0.8VDD and VOL = 0.2VDD
–
2.0
–
Output clock fall time2
tf
SO3
CL = 25pF, transition between VOH =
0.8VDD and VOL = 0.2VDD
–
2.0
–
ns
SO1, SO2
CL = 15pF, transition between VOH =
0.8VDD and VOL = 0.2VDD
–
2.0
–
Output clock jitter3
MO1
tjitter
(1-sigma)
SO3
Ta = 25°C, CL = 40pF, VO = 0.5VDD
–
20
–
Ta = 25°C, CL = 25pF, VO = 0.5VDD
–
40
–
ps
SO1, SO2
Ta = 25°C, CL = 15pF, VO = 0.5VDD
–
40
–
MO1
Output clock duty cycle2
Dt
SO3
Ta = 25°C, CL = 40pF, VO = 0.5VDD
45
50
55
Ta = 25°C, CL = 25pF, VO = 0.5VDD
45
50
55
%
SO1, SO2
Ta = 25°C, CL =15 pF, VO = 0.5VDD
45
50
55
Power-up time2, 4
tP
All outputs
excluding XTO
–
1
5
ms
1. When using an external clock input, the XTI duty should be 50% with 3.3V clock signal amplitude level. The input signal voltage should not exceed the
absolute maximum rating, otherwise damage may occur.
2. The numeric values are measured values obtained using the circuit in Figure 1 and the NPC standard evaluation board.
3. The numeric values are measured values obtained using the circuit in Figure 2 and the NPC standard evaluation board.
4. This is the time, after the supply is turned ON from the OFF state, until the output clock reaches ± 0.1% of the specified frequency.
NIPPON PRECISION CIRCUITS INC.—10