English
Language : 

D1U3CS-W-1300F-12-HX4EC Datasheet, PDF (4/5 Pages) Murata Power Solutions Inc. – 81mm Front End AC-DC Power Converter
D1U3CS-W-1300F-12-Hx4EC Series
81mm Front End AC-DC Power Converter
Signal Pin Assignment
C3
C4
D1
D2
D3
D4
MATING CONNECTOR
Supplier
FCI
Signal Name
PWR_GD
FAN_FAIL
A0
A1
S_INT
N/A
Description
Power Good signal. An active TTL HIGH signifies when the output is within regulation limits.
Fan Fail signal (failure or locked rotor)
I2C LSB (Least Significant Bit) Address Line
I2C MSB (Most Significant Bit) Address Line
System Interrupt
Reserved; no end user connection
Press Fit, Straight
---
Press Fit, Right Angle
51761-10002406AA
Solder Straight
---
Current (Amps per Pin)
N/A
N/A
N/A
N/A
N/A
N/A
Solder Right Angle
---
WIRING DIAGRAM FOR OUTPUT
D1U3CS
+12VRS (Main Output Remote Sense)
Dotted lines show optional remote sense connections.
Optional remote sense lines can be attached to a load that is a distance
away from the power supply to improve regulation at the load.
+12VRS (Main Output Remote Sense)
B2
+12V OUT
PB4-6
PB1-3 +12V GND
A2 +12VRS_RETURN
B3 +12V_ISHARE
12V load
+12V OUT PB4-6 B2
+12V GND PB1-3
+12VRS_RETURN A2
+12V_ISHARE B3
D1U3CS
A5,B5,C5,D5 +VSB
A1
A6,B6,C6,D6
PS_ON_L
+VSB load
FET, BJT, wire
or switch (debounced )
+VSB GND to turn on +12V main output
+VSB A5,B5,C5,D5
PS_ON_L A1
+VSB GND A6,B6,C6,D6
B4 PS_INHIBIT/PS_KILL
PS_INHIBIT/PS_KILL B4
CURRENT SHARING NOTES
1. Main 12VDC Output: Analogue active share bus. The ISHARE bus (Pin B3) must be connected on all sharing modules. It is not required that the SENSE signals are connected to the remote load for current share
to operate correctly.
2. Up to eight (8) power modules can be connected in parallel (non-redundant) or N+1 configuration. The current share bus is analogue bi-directional (can source or sink current from the ISHARE bus). The voltage
of the bus would measure 8VDC for a single power module at 100% load; for two (2) modules sharing a common load the ISHARE bus voltage would be 4V for a perfect 50/50 current share scenario.
3. VSTANDBY output power modules can also be connected in parallel and have internal output isolation devices; however the combined available power is limited to that available from a single power module
(3.3V or 5V; 20W) irrespective of the number of modules connected in parallel.
www.murata-ps.com/support
D1U3CS-W-1300F-12-Hx4EC.A01 Page 4 of 5