English
Language : 

URA2405LD-15WR2 Datasheet, PDF (2/9 Pages) MORNSUN Science& Technology Ltd. – DUAL/SINGLE OUTPUT DIP PACKAGING, DC-DC CONVERTER
Note: ①Series with suffix “H” are heat sink mounting; series with suffix “A2S” are chassis mounting,with suffix “A4S” are DIN-Rail mounting, for example URB2405LD-
15WHR2A2S is chassis mounting of with heat sink,URB2405LD-15WR2A4S is DIN-Rail mounting of without heat sink;If the application has a higher
requirement for heat dissipation, you can choose modules with heat sink;
②Absolute maximum rating without damage on the converter;
③For dual-output-converters the given value is for one output (for both outputs the same value);
④The efficiency of "A2S" and "A4S" is approx. 2% lower for the protection of inverse polarity.
INPUT SPECIFICATIONS
Item
Test Conditions
Input Surge Voltage (1sec.max.)
24VDC input
48VDC input
Start-up Voltage
24VDC input
48VDC input
Under Voltage Shutdown
24VDC input
48VDC input
Start-up Time
Nominal input& constant resistance load
Models ON
Ctrl*
Models OFF
Input current (Models OFF)
Input Filter
Note: *The Ctrl control pin voltage is refer to GND.
Min.
Typ.
Max.
Unit
-0.7
--
50
-0.7
--
100
--
--
9
VDC
--
--
17.8
7.5
--
--
16
--
--
--
10
--
ms
Ctrl open or connect TTL high level (2.5-12VDC)
Ctrl connect GND or low level (0-1.2VDC)
--
1
--
mA
Pi Filter
OUTPUT SPECIFICATIONS
Item
Test Conditions
Min.
Typ.
Max.
Unit
Positive Voltage Accuracy
Negative Voltage Accuracy
--
±1
±3
Output Voltage Balance
Line Regulation
Load Regulation
Cross Regulation
Transient Recovery Time
Transient Response Deviation
Temperature Drift
Dual output, balanced loads
Full load, input voltage from low to high
5% to 100% load
Dual output, main output 50% load,
Supplement output from 10% to 100% load
25% load step change
Full load
--
±0.5
±1
--
±0.2
±0.5
%
--
±0.5
±1
--
--
±5
--
300
500
µs
--
±3
±5
%
--
±0.02
--
%/°C
Ripple & Noise*
Trim
20MHz bandwidth
--
70
100
mVp-p
--
±10%
--
3.3VDC output
--
3.9
--
Output Over Voltage Protection
5VDC output
12VDC output
--
6.2
--
VDC
--
15
--
15VDC output
--
18
--
24VDC output
--
30
--
Over Current Protection
Short Circuit Protection
Input voltage range
--
160
--
%
Hiccup, Continuous, automatic recovery
Note: * Ripple and noise tested by “parallel cable” method. See detailed operation instructions at DC-DC Application Notes .
COMMON SPECIFICATIONS
Item
Test Conditions
Min.
Isolation Voltage
Input-Output,tested for 1 minute and leakage current less than 1 mA 1500
Isolation Resistance
Input-Output,test at 500VDC
1000
24VDC output
--
Isolation Capacitance
Input-Output,100KHz/0.1V
Others
--
Switching Frequency
MTBF
PWM mode
MIL-HDBK-217F@25℃
--
1000
Safety approvals
URB48XXLD-15WR2
Others
Case Material
The copyright and authority for the interpretation of the products are reserved by MORNSUN
URA_LD-15WR2 & URB_LD-15WR2
Typ.
Max.
--
--
--
--
2000
--
1000
--
300
--
--
--
UL60950, EN60950
EN60950
Aluminum Alloy
Unit
VDC
MΩ
pF
KHz
K hours
2013.11.29-A/3 Page 2of 9