English
Language : 

TA100PW Datasheet, PDF (2/5 Pages) MORNSUN Science& Technology Ltd. – Isolated Transmitter
Isolated Transmitter
TAxxxPW series
Output Specifications
Item
Operating Conditions
Fault output
--
Output type
4~20mA
0~20mA
1~5V
0~5V
0~10V
2~10V
Break alarm signal
About 21mA About 21mA About 5.25V About 5.25V About 10.5V About 10.5V
Control Area
Normal operation
Input over-range
Break alarm
Load capacity
Corresponding channel red light off
Corresponding channel red lights often flicker (0~20mA/0~5V/0~10V of Input type is no such
funstion)
Red light of the corresponding channel input disconnection(red, Single-channel 1pcs,
Dual-channel 2pcs)
≤500Ω(Output current maximum)
≥1MΩ(Output voltage maximum)
Communication port
Mini USB port
Communication protocol See "MORNSUN Modbus Protocol Rules"
Transmission Specifications
Item
Operating Conditions
Precision
Ta=25℃, Full-scale range,100% load
Zero Offset
Ta=25℃, Sin = 0,100% load
Temperature Drift
Operating temperature range of -25 ~ +71℃
Response time
Value
0.1%F.S.
0.1%F.S.
0.0035%F.S./ ℃
< 0.5s
General Specifications
Item
Operating Conditions
Electrical Isolation
1Min leakage current ≤5mA
Insulation Resistance Signal input port, signal output port
Value
Field area and control area:2KVAC/3KVDC,1min,leakage current ≤5mA
Output and power supply,2KVAC/3KVDC,1min,leakage current ≤5mA
100MΩ,500VDC
Physical Specifications
Casing Material
PA66
Safety Class
IP20 (IEC60529 / EN60529)
Dimensions
35mm DIN-rail package: T-rail card package (DIN50022), pluggable connection pin, thickness 12.5mm
Weight
1 input 1 output: 100g;2 input 2 output & 1 input 2 output: 135g, typ
Cooling
Free convection
EMC Specifications
Conducted Emission
EMI
Radiated Emission
Electrostatic Discharge
Radiation Iimmunity
EMS
EFT
Surge Immunity
EMS
Conducted Disturbance Immunity
CISPR22/EN55022 CLASS A
CISPR22/EN55022 CLASS A
IEC/EN61000-4-2 Contact ±4KV/Air ±8KV
IEC/EN61000-4-3 10V/m
IEC/EN61000-4-4 power supply port ±2KV
IEC/EN61000-4-4 signal port ±1KV
IEC/EN61000-4-5 power supply port ±1KV/2KV
IEC/EN61000-4-5 signal port ±1KV (line-to-ground)
IEC/EN61000-4-6 3 Vr.m.s
perf. Criteria B
perf. Criteria A
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria B
perf. Criteria A
2014.02.18-A/2
Page 2 of 5