English
Language : 

PS21562-P Datasheet, PDF (4/9 Pages) Mitsubishi Electric Semiconductor – AC100V~200V inverter drive for small power motor control.
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
PS21562-P
TRANSFER-MOLD TYPE
INSULATED TYPE
THERMAL RESISTANCE
Symbol
Parameter
Condition
Limits
Min.
Typ.
Max. Unit
Rth(j-f)Q
Rth(j-f)F
Junction to case thermal
Inverter IGBT part (per 1/6 module)
resistance
(Note 3) Inverter FWD part (per 1/6 module)
—
—
6.0 °C/W
—
—
6.5 °C/W
Note 3: Grease with good thermal conductivity should be applied evenly with about +100µm~+200µm on the contacting surface of DIP-IPM
and heat-sink.
ELECTRICAL CHARACTERISTICS (Tj = 25°C, unless otherwise noted)
INVERTER PART
Symbol
Parameter
VCE(sat)
VEC
ton
trr
tc(on)
toff
tc(off)
ICES
Collector-emitter saturation
voltage
FWD forward voltage
Switching times
Collector-emitter cut-off
current
Condition
VD = VDB = 15V
IC = 5A, Tj = 25°C
VIN = 5V
IC = 5A, Tj = 125°C
Tj = 25°C, –IC = 5A, VIN = 0V
VCC = 300V, VD = VDB = 15V
IC = 5A, Tj = 125°C, VIN = 0 ↔ 5V
Inductive load (upper-lower arm)
VCE = VCES
Tj = 25°C
Tj = 125°C
Limits
Min.
Typ.
Max. Unit
—
1.60 2.10
—
1.70 2.20
V
—
1.50 2.00
V
0.60
1.20
1.80
µs
—
0.30
—
µs
—
0.40
0.60
µs
—
1.30
2.00
µs
—
0.50
0.80
µs
—
—
—
—
1
mA
10
CONTROL (PROTECTION) PART
Symbol
Parameter
Condition
Limits
Unit
Min.
Typ.
Max.
ID
Circuit current
VD = VDB = 15V Total of VP1-VNC, VN1-VNC
—
VIN = 5V
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS —
VD = VDB = 15V Total of VP1-VNC, VN1-VNC
—
—
5.00
—
0.40
mA
—
7.00
VIN = 0V
VUFB-VUFS, VVFB-VVFS, VWFB-VWFS —
—
0.55
VFOH
VFOL
Fault output voltage
VSC = 0V, FO circuit pull-up to 5V with 10kΩ
VSC = 1V, IFO = 1mA
4.9
—
—
V
—
—
0.95
V
VSC(ref) Short circuit trip level
Tf = –20~100°C, VD = 15V
(Note 4)
0.45
—
0.52
V
IIN
Input current
VIN = 5V
1.0
1.5
2.0
mA
UVDBt
Trip level
10.0
—
12.0
V
UVDBr
UVDt
Control supply under-voltage
protection
Tj ≤ 125°C
Reset level
Trip level
10.5
—
12.5
V
10.3
—
12.5
V
UVDr
Reset level
10.8
—
13.0
V
tFO
Fault output pulse width
CFO = 22nF
(Note 5)
1.0
1.8
—
ms
Vth(on)
Vth(off)
ON threshold voltage
OFF threshold voltage
Applied between UP, VP, WP-VNC, UN, VN, WN-VNC
2.1
2.3
2.6
V
0.8
1.4
2.1
V
Note 4 : Short circuit protection is functioning only for the lower-arms. Please select the external shunt resistance such that the SC trip-level is
less than 2.0 times of the current rating.
5 : Fault signal is asserted corresponding to a short circuit or lower side control supply under-voltage failure. The fault output pulse width tFO
depends on the capacitance value of CFO according to the following approximate equation : CFO = 12.2 ✕ 10-6 ✕ tFO [F].
Sep. 2005