English
Language : 

M66271FP Datasheet, PDF (15/21 Pages) Mitsubishi Electric Semiconductor – OPERATION PANEL CONTROLLER
MITSUBISHI <DIGITAL ASSP>
M66271FP
OPERATION PANEL CONTROLLER
ABSOLUTE MAXIMUM RATINGS (Ta=0 – +70˚C unless otherwise noted)
Symbol
Parameter
Conditions
Ratings
Unit
VDD
VI
VO
IO
Pd
Tstg
Supply voltage
Input voltage
Output voltage
Output current
Power dissipation
Storage temperature
–0.3 – +6.5
V
–0.3 – VDD+0.3
V
–0.3 – VDD+0.3
V
±10
mA
600
mW
–55 – +150
˚C
RECOMMENDED OPERATING CONDITIONS (Ta=0 – +70˚C unless otherwise noted)
Symbol
Parameter
VDD
VSS
Supply voltage
Supply voltage
Conditions
Limits
Unit
Min.
Typ.
Max.
4.5
5.0
5.5
V
0
V
VI
Input voltage
0
VDD
V
VO
Output voltage
0
VDD
V
Topr Operating temperature
0
+25
+70
˚C
ELECTRICAL CHARACTERISTICS (VDD=5V±10%, Ta=0 – +70˚C unless otherwise noted)
Symbol
Parameter
Conditions
Limits
Unit
Min.
Typ.
Max.
VIH High-level input voltage All inputs
VDD=5.5V
2.2
except for
OSC1,RESET
VIL Low-level input voltage and MPUSEL VDD=4.5V
V
0.8
V
VIH High-level input voltage
OSC1
VIL Low-level input voltage
VDD=5.5V
VDD=4.5V
VT +
VT –
VOH
VOL
VOH
VOL
Positive-going
threshold voltage
Negative-going
threshold voltage
High-level output voltage
Low-level output voltage
MPUSEL,
RESET
All outputs
except for
OSC2 and
outputs of
D<15:0>
VDD=5.0V
VDD=5.0V
IOH=–4mA
VDD=4.5V
IOL= 4mA
High-level output voltage
OSC2
Low-level output voltage
IOH=–50uA
VDD=4.5V
IOL= 50uA
3.5
2.3
1.25
4.1
4.1
V
1.0
V
3.7
V
2.3
V
V
0.4
V
V
0.4
V
IIH High-level input current
VDD=5.5V,VI=VDD
10
µA
IIL
Low-level input current
VDD=5.5V,VI=VSS
IOZH
IOZL
Off-state high-level
output current
Off-state low-level
output current
D<15:0>
IDD(A)
Operating supply current
(Average)
IDD(S) Stand-by supply current
VDD=5.5V,VO=VDD
VDD=5.5V,VO=VSS
VDD=5.5V,VI=VDD or VSS
fosc=10MHz,Output=open
VDD=5.5V,
IOCS,MCS=VDD
Other's VI=VDD or VSS (valid)
–10
µA
10
µA
–10
µA
40
mA
500
µA