English
Language : 

PS21267-P-AP Datasheet, PDF (10/10 Pages) Mitsubishi Electric Semiconductor – AC100V~200V three-phase inverter drive for small power motor control.
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
PS21267-P/AP
TRANSFER-MOLD TYPE
INSULATED TYPE
Fig. 10 EXAMPLE OF TYPICAL DIP-IPM APPLICATION CIRCUIT
5V line
C1:Tight tolerance temp-compensated electrolytic type
C2,C3: 0.22~2µF R-category ceramic capacitor for noise filtering.
(Note: The capacitance value depends on the PWM control used in the applied system.)
C2 VUFB
C1 VUFS
VP1
C3
UP
HVIC1
VCC
VB
IN
HO
DIP-IPM
P
C2 VVFB
C1 VVFS
VP1
C3
VP
C2 VWFB
C1 VWFS
VP1
C3
WP
VPC
COM VS
HVIC2
VCC
VB
IN
HO
COM VS
HVIC3
VCC
VB
IN
HO
COM VS
U
V
M
W
LVIC
UOUT
VN1
VCC
C3
VOUT
15V line
UN
VN
WN
Fo
VNC
UN
VN
WN
Fo
GND
WOUT
VNO
CIN
CFO
CFO
CIN
If this wiring is too long,
short circuit might be
caused.
N
C
C4(CFO)
A
B R1
C5
Shunt
Resistor
The long wiring of GND might generate If this wiring is too long, the SC level
N1
noise on input and cause IGBT to
fluctuation might be larger and cause
be malfunction.
SC malfunction.
Note 1 : To prevent the input signals oscillation, the wiring of each input should be as short as possible. (Less than 2-3cm)
2 : By virtue of integrating an application specific type HVIC inside the module, direct coupling to MCU terminals without any opto-coupler
or transformer isolation is possible.
3 : FO output is open drain type. This signal line should be pulled up to the positive side of the 5V power supply with approximately 10kΩ
resistor.
4 : FO output pulse width is determined by the external capacitor between CFO and VNC terminals (CFO). (Example : CFO = 22nF → tFO
= 1.8ms (typ.))
5 : The logic of input signal is high-active. The DIP-IPM input signal section integrates a 2.5kΩ (min) pull-down resistor. If using external
RC filter, pay attention to satisfy the turn-on/off threshold voltage requirement.
6 : To prevent malfunction of protection, the wiring of A, B, C should be as short as possible.
7 : Please set the R1C5 time constant in the range 1.5~2µs.
8 : Each capacitor should be located as nearby the pins of the DIP-IPM as possible.
9 : To prevent surge destruction, the wiring between the smoothing capacitor and the P, N1 pins should be as short as possible. Approxi-
mately a 0.1~0.22µF snubber capacitor between the P-N1 pins is recommended.
10 : To prevent ICS from surge destruction, it is recommended to insert a Zener diode (24V, 1W) between each control supply terminals.
Oct. 2005