English
Language : 

PS21212 Datasheet, PDF (1/8 Pages) Mitsubishi Electric Semiconductor – TRANSFER-MOLD TYPE INSULATED TYPE
MITMSUITBSIUSBHISSHEIMSIECMOINCDOUNCDTUOCRTO<RDu<aDl-uIna-lL-Iinn-eLiPnaecPkacgkeaIgneteIlnlitgeellnigtePnotwPeorwMeor dMuoled>ule>
PS21PS22112212
TRATNRSAFNESRF-EMRO-MLDOLTDYPTEYPE
INSIUNLSAUTLEADTETDYPTEYPE
PS21212
INTEGRATED POWER FUNCTIONS
600V/5A low-loss 3rd generation IGBT inverter bridge for 3
phase DC-to-AC power conversion (Fig. 2)
Application Motor Ratings : Power : 0.2kW, sinusoidal, PWM
Frequency=15kHz
100% load current : 1.5A (rms)*
150% load current : 2.25A (rms)*,
1 minute.
*(Note) : The motor current is assumed to be sinusoidal and
the peak current value is defined as : lO ! √ 2
INTEGRATED DRIVE, PROTECTION AND SYSTEM CONTROL FUNCTIONS
• For upper-leg IGBTS : Drive circuit, High voltage isolated high-speed level shifting, Control circuit under-voltage (UV) protection.
Note : Bootstrap supply scheme can be applied (Fig. 2).
• For lower-leg IGBTS : Drive circuit, Control curcuit under-voltage protection (UV), Short circuit protection (SC). (Fig. 3)
• Fault signaling : Corresponding to a SC fault (Low-side IGBT) or a UV fault (Low-side supply).
• Input interface : 5V line CMOS/TTL compatible, Schmitt Trigger receiver circuit.
APPLICATION
AC100V~200V three-phase inverter drive for small power (0.2 kW) motor control.
Fig. 1 PACKAGE OUTLINES
2.8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
2-φ4.5
22
23
24
25
26
10
10
10
20
3.8
67
79
TERMINALS CODE
1. UP
4. VUFS
2. VP1 5. VP
3. VUFB 6. VP1
7. VVFB
8. VVFS
9. WP
10. VP1 13. VWFS 16. CIN 19. UN
11. VPC 14. VN1 17. CFO 20. VN
12. VWFB 15. VNC 18. Fo 21. WN
22. P
23. U
24. V
25. W
26. N
Aug. 1999