English
Language : 

XP1073-BD Datasheet, PDF (9/10 Pages) Mimix Broadband – 34.0-37.0 GHz GaAs MMIC Power Amplifier
34.0-37.0 GHz GaAs MMIC
Power Amplifier
February 2010 - Rev 16-Feb-10
P1073-BD
MTTF at CW Graph
These numbers were calculated based upon accelerated life test information received from the fabricating foundry and extensive thermal modeling/
finite element analysis done at Mimix Broadband. The values shown here are only to be used as a guideline against the end application requirements
and only represent reliability information under one bias condition. Ultimately bias conditions and resulting power dissipation along with the
practical aspects, i.e. thermal material stack-up, attach method of die placement are the key parts in determining overall reliability for a specific
application, see previous pages. If the data shown below does not meet your reliability requirements or if the bias conditions are not within your
operating limits please contact technical sales for additional information.
1.0E+06
XP1073-BD Vd=6.0 V, Id1=320 mA
Id2=640 mA, Id3=1280 mA, Id4=2560 mA
1.0E+05
1.0E+04
1.0E+03
1.0E+02
1.0E+01
55
65
75
85
95
105
115
125
Backplate Temperature (deg C)
1.00E+08
XP1073-BD Vd=6.0 V, Id1=320 mA
Id2=640 mA, Id3=1280 mA, Id4=2560 mA
1.00E+07
1.00E+06
1.00E+05
1.00E+04
1.00E+03
55
65
75
85
95
105
115
125
Backplate Temperature (deg C)
4.8
4.7
4.6
4.5
4.4
4.3
4.2
4.1
4.0
3.9
3.8
55
XP1073-BD Vd=6.0 V, Id1=320 mA
Id2=640 mA, Id3=1280 mA, Id4=2560 mA
65
75
85
95
105
115
125
Backplate Temperature (deg C)
270
260
250
240
230
220
210
200
190
180
170
55
XP1073-BD Vd=6.0 V, Id1=320 mA
Id2=640 mA, Id3=1280 mA, Id4=2560 mA
65
75
85
95
105
115
125
Backplate Temperature (deg C)
Mimix Broadband, Inc., 10795 Rockley Rd., Houston, Texas 77099
Tel: 281.988.4600 Fax: 281.988.4615 mimixbroadband.com
Page 9 of 10
Characteristic Data and Specifications are subject to change without notice. ©2010 Mimix Broadband, Inc.
Export of this item may require appropriate export licensing from the U.S. Government. In purchasing these parts, U.S. Domestic customers accept
their obligation to be compliant with U.S. Export Laws.