English
Language : 

HAL566 Datasheet, PDF (9/21 Pages) Micronas – Two-Wire Hall Effect Sensor Family
HAL55x, HAL56x
3.7. Magnetic Characteristics Overview at TJ = –40 °C to +170 °C, VDD = 4 V to 24 V,
Typical Characteristics for VDD = 12 V
Magnetic flux density values of switching points.
Positive flux density values refer to the magnetic south pole at the branded side of the package.
Sensor
Switching Type
HAL 556
unipolar
HAL 560
unipolar
inverted
HAL 566
unipolar
inverted
Parameter
TJ
–40 °C
25 °C
100 °C
170 °C
–40 °C
25 °C
100 °C
170 °C
–40 °C
25 °C
100 °C
170 °C
On point BON
Min.
Typ.
Max.
3.4
6.3
7.7
3.4
6
7.4
3.2
5.5
7.2
2.8
5
7.6
41
46.5
52
41
46.6
52
41
45.7
52
38
44.2
50
2.1
4
5.9
2
3.9
5.7
1.85
3.8
5.7
1
3.4
6.3
Off point BOFF
Min.
Typ.
Max.
2.1
4.2
5.9
2
3.8
5.7
1.9
3.7
5.7
1
3.5
6.2
47
53
59
46
52.5
58.5
45
41.1
57.5
42
49
55.5
3.4
6
7.7
3.4
5.9
7.2
3.25
5.6
7
2.2
4.8
7.6
Hysteresis BHYS
Unit
Min.
Typ.
Max.
0.8
2.1
3
mT
0.5
1.8
2.8
mT
0.3
1.8
2.8
mT
0.2
1.5
3.2
mT
4
6.5
10
mT
3
6
9
mT
2
5.4
8
mT
2
4.8
8
mT
0.8
2
2.8
mT
0.5
2
2.7
mT
0.3
1.8
2.6
mT
0.2
1.4
3
mT
Note: For detailed descriptions of the individual types, see pages 12 and following.
Micronas