HAL1821UA-A Datasheet, PDF (12/14 Pages) Micronas – Linear Hall-Effect Sensor Family in SOT89B Package
HAL 1821...HAL 1823
DATA SHEET
1.03
1.02
1.01
1.00
0.99
1.001
0.993
ideal 200 ppm/k
least-square-fit straight-line of
normalized measured data
measurement example of real
sensor, normalized to achieve a
value of 1 of its least-square-fit
straight-line at 25 °C
0.98
-50 -25 -10 0
25 50 75 100 125 150 175
temperature [°C]
Fig. 3–2: Definition of Sensitivity Error ES.
3.7.1. Definition of Sensitivity Error ES
ES is the maximum of the absolute value of 1 minus
the quotient of the normalized measured value1) over
the normalized ideal linear2) value:
In the example shown in Fig. 3–2 the maximum error
occurs at 10 °C:
ES = maxabsm-i--d--ee---aa---sl – 1
Tmin, Tmax
ES = 1---.--0---0---1- – 1 = 0.8%
0.993
1) normalized to achieve a least-square-fit straight-line
that has a value of 1 at 25 °C
2) normalized to achieve a value of 1 at 25 °C
12
Aug. 2, 2013; DSH000162_001EN
Micronas