64 Mbit Multi-Purpose Flash Plus
SST39VF6401B / SST39VF6402B
Operations
Not Recommended for New Designs
Table 5: Operation Modes Selection
Mode
Read
Program
Erase
CE#
VIL
VIL
VIL
OE#
VIL
VIH
VIH
WE#
VIH
VIL
VIL
DQ
DOUT
DIN
X1
Standby
Write Inhibit
Product Identification
Software Mode
VIH
X
X
VIL
X
X
VIL
VIL
1. X can be VIL or VIH, but no other value.
X High Z
X High Z/ DOUT
VIH High Z/ DOUT
VIH
Address
AIN
AIN
Sector or block address,
XXH for Chip-Erase
X
X
X
See Table 6
T5.0 25008
Table 6: Software Command Sequence
Command
Sequence
1st Bus
Write Cycle
2nd Bus
Write Cycle
3rd Bus
Write Cycle
4th Bus
Write Cycle
5th Bus
Write Cycle
6th Bus
Write Cycle
Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2 Addr1 Data2
Word-Program
555H AAH 2AAH 55H 555H A0H WA3 Data
Sector-Erase
Block-Erase
Chip-Erase
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H SAX4 50H
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H BAX4 30H
555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H 555H 10H
Erase-Suspend
XXXXH B0H
Erase-Resume
XXXXH 30H
Query Sec ID5
555H AAH 2AAH 55H 555H 88H
User Security ID
Word-Program
User Security ID
Program Lock-Out
555H AAH 2AAH 55H 555H A5H WA6 Data
555H AAH 2AAH 55H 555H 85H XXH6 0000H
Software ID Entry7,8 555H AAH 2AAH 55H 555H 90H
CFI Query Entry
555H AAH 2AAH 55H 555H 98H
Software ID Exit9,10 555H AAH 2AAH 55H 555H F0H
/CFI Exit/Sec ID Exit
Software ID Exit9,10 XXH F0H
/CFI Exit/Sec ID Exit
1. Address format A10-A0 (Hex).
Addresses A11- A21 can be VIL or VIH, but no other value, for Command sequence for SST39VF640xB.
2. DQ15-DQ8 can be VIL or VIH, but no other value, for Command sequence
3. WA = Program Word address
4. SAX for Sector-Erase; uses AMS-A11 address lines
BAX, for Block-Erase; uses AMS-A15 address lines
AMS = Most significant address
AMS = A21 for SST39VF640xB
5. With AMS-A4 = 0; Sec ID is read with A3-A0,
SST ID is read with A3 = 0 (Address range = 000000H to 000007H),
User ID is read with A3 = 1 (Address range = 000010H to 000017H).
Lock Status is read with A7-A0 = 0000FFH. Unlocked: DQ3 = 1 / Locked: DQ3 = 0.
6. Valid Word-Addresses for Sec ID are from 000000H-000007H and 000010H-000017H.
T6.0 25008
© 2015
DS20005008B
08/15
13