English
Language : 

TH8055 Datasheet, PDF (10/15 Pages) Micro Electronics – Single Wire CAN Transceiver
TH8055
Single Wire CAN Transceiver
Bus loading requirements
Parameter
Symbol
Min
Typ
Max
Unit
Number of system nodes
2
32
Network distance between any two ECU nodes
Bus length
60
m
Node series Inductor Resistance
Rind
2.3
Ω
EMC Inductor voltage drop
Vind
0.3
V
Ground offset voltage
Vgoff
0.8
V
Device capacitance (unit load)
Cul
198
220
242
pF
Network total capacitance
Ctl
396
13700
pF
Device resistance (unit load)
Rul
9009
9100
9191
Ω
Device resistance (min load)
Rmin
2000
Ω
Network total resistance
Rtl
270
4596
Ω
Network time constant [1]
τ
1
4
µs
High speed mode network resistance to GND
Rload
100
185
Ω
Timing Diagrams
VTxD
50%
t
tT
VCANH
70%
30%
VRxD
50%
tR
tD
t
tF
tDR
t
Figure 2 - Input/Output Timing
[1] The network time constant incorporates the bus wiring capacitance. The minimum value is selected to limit radiated
emission. The maximum value is selected to ensure proper communication modes. Not all combinations of R and C are
possible.
390108055
Rev. 1.1a
Page 10 of 15
Jan 2002