English
Language : 

MIC3002 Datasheet, PDF (55/65 Pages) Micrel Semiconductor – FOM Management IC with Internal Calibr ation
Micrel, Inc.
MIC3002
IBIAS Fault Threshold (IBFLT)
Bias current fault threshold
D[7]
read/write
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
read/write
D[2]
read/write
D[1]
read/write
D[0]
read/write
Default Value
0000 0000b = 00h
Serial Address
A6h
Byte Address
7 = 07h
A valid OEM password is required for access to this register. This register is non-volatile and will be maintained through power
and reset cycles. A fault is generated if the bias current is higher than IBFLT value set in this register.
Transmit Power Fault Threshold (TXFLT)
D[7]
read/write
Default Value
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
read/write
0000 0000b = 00h
D[2]
read/write
D[1]
read/write
D[0]
read/write
Serial Address
A6h
Byte Address
8 = 08h
A valid OEM password is required for access to this register. This register is non-volatile and will be maintained through power
and reset cycles. A fault is generated if the Transmit power is higher than TXFLT value set in this register.
Loss-Of-Signal Threshold (LOSFLT)
D[7]
read/write
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
read/write
D[2]
read/write
D[1]
read/write
D[0]
read/write
Default Value
Serial Address
Byte Address
0000 0000b = 00h
A6h
9 = 09h
A valid OEM password is required for access to this register. This register is non-volatile and will be maintained through power
and reset cycles. A fault is generated if the received power is lower than LOSFLT value set in this register.
Byte
D[7:4]
Function
Receive loss-of-signal threshold
Operation
Read/write; non-volatile.
Fault Suppression Timer (FLTTMR)
Fault suppression interval in increments of 0.5ms
D[7]
read/write
Default Value
Serial Address
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
read/write
0000 0000b = 00h
A6h
D[2]
read/write
D[1]
read/write
D[0]
read/write
Byte Address
10 = 0Ah
Saturation faults are suppressed for a time, tFLTTMR, following laser turn-on. This avoids nuisance tripping while the APC loop
starts up. The length of this interval is (FLTTMRx 0.5ms), typical. A value of zero will result in no fault suppression. A valid
OEM password is required for access to this register. This register is non-volatile and will be maintained through power and
reset cycles.
July 2007
55
M9999-073107-B
hbwhelp@micrel.com or (408) 955-1690