TABLE 29-20: PLL CLOCK TIMING SPECIFICATIONS
AC CHARACTERISTICS
Standard Operating Conditions: 1.8V to 3.6V PIC24F32KA3XX
2.0V to 5.5V PIC24FV32KA3XX
Operating temperature -40°C  TA  +85°C for Industrial
Param
No.
Sym
Characteristic(1)
Min
Typ(2)
Max Units
Conditions
OS50 FPLLI PLL Input Frequency
Range
4
—
8
MHz ECPLL, HSPLL modes,
-40°C  TA  +85°C
OS51 FSYS PLL Output Frequency
16
—
32
MHz -40°C  TA  +85°C
Range
OS52 TLOCK PLL Start-up Time
(Lock Time)
—
1
2
ms
OS53 DCLK CLKO Stability (Jitter)
-2
1
2
% Measured over 100 ms period
Note 1: These parameters are characterized but not tested in manufacturing.
2: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance only
and are not tested.
TABLE 29-21: AC CHARACTERISTICS: INTERNAL FRC ACCURACY
AC CHARACTERISTICS
Standard Operating Conditions: 1.8V to 3.6V PIC24F32KA3XX
2.0V to 5.5V PIC24FV32KA3XX
Operating temperature -40°C  TA  +85°C for Industrial
Param
No.
Characteristic
Min Typ Max Units
Conditions
F20
Internal FRC Accuracy @ 8 MHz(1)
FRC
-2
—
+2
%
+25°C
3.0V  VDD  3.6V, F Device
3.2V  VDD  5.5V, FV Device
-5
—
+5
% -40°C  TA +85°C 1.8V  VDD  3.6V, F Device
2.0V  VDD  5.5V, FV Device
Note 1: Frequency calibrated at 25°C and 3.3V. OSCTUN bits can be used to compensate for temperature drift.
TABLE 29-22: AC CHARACTERISTICS: INTERNAL RC ACCURACY
AC CHARACTERISTICS
Standard Operating Conditions: 1.8V to 3.6V PIC24F32KA3XX
2.0V to 5.5V PIC24FV32KA3XX
Operating temperature -40°C  TA  +85°C for Industrial
Param
No.
Characteristic
Min Typ Max Units
Conditions
LPRC @ 31 kHz(1)
F21
-15
—
15
%
Note 1: Change of LPRC frequency as VDD changes.
TABLE 29-23: INTERNAL RC OSCILLATOR SPECIFICATIONS
AC CHARACTERISTICS
Standard Operating Conditions: 1.8V to 3.6V PIC24F32KA3XX
2.0V to 5.5V PIC24FV32KA3XX
Operating temperature -40°C  TA  +85°C for Industrial
-40°C  TA  +125°C for Extended
Param
No.
Sym
Characteristic(1)
Min
Typ
Max Units
Conditions
TFRC FRC Start-up Time
TLPRC LPRC Start-up Time
—
5
—
s
—
70
—
s
DS39995B-page 282