English
Language : 

MIC280_06 Datasheet, PDF (19/23 Pages) Micrel Semiconductor – Precision IttyBitty Thermal Supervisor
MIC280
Micrel
Remote Temperature Low Limit Low-Byte Register (TLOW1l)
8-bits, read/write
Remote Temperature Low Limit Low-Byte Register
D[7]
read/write
D[6]
read/write
D[5]
read/write
D[4]
read/write
D[3]
reserved
D[2]
reserved
D[1]
reserved
Low temperature limit for remote zone, least significant bits.
Reserved - always reads zero.
D[0]
reserved
Bit
Function
Operation
D[7:4]
Low temperature limit for the remote zone, least significant bits.
Read/write
D[3:0]
Reserved
Always reads as zeros.
Power-up default value:
0000 0000b = 00h (0°C)
Read/Write command byte: 0001 0100b = 14h
Each LSB represents one-sixteenth degree centigrade. The values are in a binary format such that 1/16th°C (0.0625°C) is
reported as 0001 0000b. See Temperature Data Format (above) for more details.
Any writes to a temperature limit register will result in the corresponding fault queue being purged and reset.
D[7]
read/write
D[6]
read/write
Remote Over-Temperature Limit Register (CRIT1)
8-bit, read/write
Remote Over-Temperature Limit Register
D[5]
read/write
D[4]
read/write
D[3]
read/write
D[2]
read/write
Over-temperature limit for remote zone.
D[1]
read/write
D[0]
read/write
Bit
Function
Operation
D[7:0]
Over-temperature limit for the remote zone.
Read/write
Power-up default value:
0110 0100b = 64h (100°C)
Read/Write command byte: 0001 1001b = 19h
Each LSB represents one degree centigrade. The values are in a two’s complement binary format such that 0°C is reported
as 0000 0000b. SeeTemperature Data Format (above) for more details.
Any writes to a temperature limit register will result in the corresponding fault queue being purged and reset.
May 2006
19
MIC280