English
Language : 

MIC280_06 Datasheet, PDF (15/23 Pages) Micrel Semiconductor – Precision IttyBitty Thermal Supervisor
MIC280
Micrel
D[7]
read/write
IM7
D[6]
read/write
IM6
Interrupt Mask Register (IMASK)
8-bits, read/write
Interrupt Mask Register
D[5]
read/write
D[4]
read/write
D[3]
read/write
D[2]
read/write
IM 5
IM 4
IM 3
IM 2
D[1]
read/write
IM 1
D[0]
read/write
IM0
Bit(s)
IM7
IM6
IM5
IM4
IM3
IM2
IM1
IM0
Function
Operation*
Data ready event mask
1 = enabled, 0 = disabled
Local high temperature event mask
1 = enabled, 0 = disabled
Local low temperature event mask
1 = enabled, 0 = disabled
Remote high temperature event mask
1 = enabled, 0 = disabled
Remote low temperature event mask
1 = enabled, 0 = disabled
Diode fault mask
1 = enabled, 0 = disabled
Remote over-temperature event mask
1 = enabled, 0 = disabled
Local over-temperature event mask
1 = enabled, 0 = disabled
Power-up default value:
Read/Write command byte:
0000 0111b = 07h (Over-temp. and diode faults enabled)
0000 0100b = 04h
D[7]
read/write
D[6]
read/write
Local Temperature High Limit Register (THIGH0)
8-bits, read/write
Local Temperature High Limit Register
D[5]
read/write
D[4]
read/write
D[3]
read/write
D[2]
read/write
D[1]
read/write
High temperature limit for local zone.
D[0]
read/write
Bit
Function
Operation
D[7:0]
High temperature limit for the local zone.
Read/write
Power-up default value:
0011 1100b = 3Ch (60°C)
Read/Write command byte: 0000 0101b = 05h
Each LSB represents one degree centigrade. The values are in a two’s complement binary format such that 0°C is reported
as 0000 0000b. See Temperature Data Format (above) for more details.
Any writes to a temperature limit register will result in the corresponding fault queue being purged and reset.