The input EN has an internal pull down resistor. If
EN=high, the internal pull down current is switched off to
minimize the quiescent current.
RESET Output
The RESET output is switched from low to high if VS is
switched on and VCC>VRESEIN after the time tRES.
If the voltage VCC drops below VRES1 or VRES2 then the RESET
output is switched from high to low after the time trr has been
reached.
The voltage level for VRES1 and VRES2 and the
corresponding times tRES can be programmed via the
analogue input VTR.
Wake up with BUS traffic
If the regulator is put in standby mode it can be woken
up with the BUS interface. Every pulse on the BUS (high
pulse or low pulse) with a pulse width of min. 45 µ s will
switch on the regulator.
After the BUS has woken up the regulator, it can only be
switched off with a high level followed by a low level on
the EN pin.
Reset Programming on VTR
With the VTR pin the reset switches off levels and delay
time can be programmed.
The voltage on VCC influences the reset function.
VTR-Mode
VTR = GND
VTR = VCC
VTR with R ≥ 50k Ω to GND
VTR with R ≥ 50k Ω to VCC
VRES
VRES = VRES1 = 3.15V
VRES = VRES2 = 4.65V
VRES = VRES1 = 3.15V
VRES = VRES2 = 4.65V
tRes
100ms
100ms
15ms
15ms
VTR-Programming
The voltage on VTR input is read out if the voltage at this
pin is higher than VRESEIN . This value defines the reset
switch off voltage VRES. With the next oscillator cycle it
switches on the pull up current source if VTR=low or the
pull down current source if VTR=high. The sources are
active for one oscillator cycle. The level changes during
this procedure on VTR, which depends on the external
pull up or pull down resistors control the reset time tRes
Temperature Limitation
If the junction temperature 150ºC < Tj < 170ºC the over
temperature recognition will be active and the regulator
voltage and the BUS driver will be switched off. After Tj
falls below 140ºC the TH3122 will be initialized,
independently of the voltage levels on EN and BUS.
The function of the TH3122 is possible between TAmax
and the switch off temperature, but small parameter
differences can appear.
Low Voltage Detection VS
Low voltage on VS is monitored on SENSE output.
If VS has reached the level of VS =6.8V then the SENSE
output generates low level. The normal
operating range is VS > 7.8V and the SENSE output
generates a high level.
Universal Comparator
The TH3122 consist of a universal comparator for
general use. The positive input of this comparator is
connected to the pin SI. The input voltage range of SI is
0V...VS. The input voltage is compared with a fixed
reference voltage at high or low level and the comparator
output SO drives a 5V digital signal.