English
Language : 

MLX90288 Datasheet, PDF (4/19 Pages) Melexis Microelectronic Systems – SMD Programmable Linear Hall Sensor IC Featuring Analog Ratiometric Output
MLX90288
SMD Programmable Linear Hall Sensor IC
Featuring Analog Ratiometric Output
Exposing a part to absolute maximum ratings for extended periods of time may affect device reliability.
5.2 Electrical Specification
Operating parameter valid for TA = – 40°C to + 150°C & VDD = + 4.5V to + 5.5V (unless specified otherwise).
Item
Symbol
Remark
Min Typ Max Unit
Supply Voltage
Supply Current
VDD
Guaranteed spec operation 4.5
5
5.5
V
IDD
Worst case (min RPD, max
VDD)
-
8.8
10
mA
Regulated Voltage
VREG
Internal voltage
3.0 3.3 3.6
V
Reset Voltage
VPORRISE Output is high impedant for 2.5
VPORFALL
VPOR < VDD < VUNDER
2.4
3.4
V
3.3
V
Undervoltage Threshold
VUNDERRISE
VUNDERFALL
Operating if VDD > VUNDER
3.4
3.3
4.4
V
4.3
V
Programming Voltage(1)
VPROGRISE
VPROGFALL
Device not locked
6.2
6.1
Overvoltage Threshold(2)
VOVER
Disconnect VPROT from VDD
8.4
7.2
V
7.1
V
14
V
Load Resistance Range
RPD
Pull-down to GND
8
10 330
kΩ
Load capacitor range
CL
Between OUT and GND
47
1000 nF
Output Saturation
Voltage(3)
VSATHI
VSATLO
Including RPD
Including RPD
96
100 %VDD
0
2
%VDD
Output Current
IOUTLIMGND
Output amplifier sourcing
strength
2
5
8
mA
Limitation(4)
IOUTLIMVDD
Output amplifier sinking
strength
2
5
8
mA
Supply Current
Limitation
IVDDLIM
Same condition as above
5
18
mA
Output Diagnostic Band
Leakage Current(5)
IDIAGLO
Leakage current over TA
VDD=5V
500
nA
Output Diagnostic Level
VDIAGLO
Leakage current over TA
and VDD span
RPD x
IDIAGLO
V
Table 2: Electrical Specification
(1) The programming voltage defines the threshold at which the ASIC goes into PTC mode, where the
output pin becomes bidirectional. Write access is eventually defined by the locking bits as described
in Section 6.1
(2) The overvoltage threshold will disconnect all internal supplies (Vana, Vdig & Vprot) from VDD; the
output becomes high impedant.
(3) The saturation voltage is the rail voltage the output amplifier can reach actively with RPD connected.
(4) The maximum current the output stage can deliver to keep its DC value, in case the output is pulled
to one of the rails by means of an external power supply, while VDD = 5V.
(5) The leakage current is in fact the current sourced by the output in case of an OBD detection (broken
ground), where the output goes into high-Z mode. For better contacting at the connectors over
lifetime and bigger rail-to-rail operation, the smaller pull-down resistors from this specification are
recommended at ECU side.
3901090288
Rev 002
Page 4 of 19
May/12