MLX90367
Triaxis® Position Sensor IC feat. SENT
(ii) k
When the mapping (B1=X, B2=Y) is NOT selected, k defines the sensitivity mismatch factor that is applied
on B1or B2 (according to parameter SEL_k – see below). When the mapping (B1=X, B2=Y) is selected,
this parameter is “don’t care”.
This parameter is trimmed at factory for mapping (B1=Z, B2=X). Melexis recommends to fine trim it when
a smaller linearity error (Le) is required and a different mapping than (B1=X, B2=Y) is selected.
(iii) SEL_k
When the mapping (B1=X, B2=Y) is NOT selected, SEL_k defines the component on which the sensitivity
mismatch factor k (see above): SEL_k = 0 means B1→ k ⋅ B1 and SEL_k = 1 means B2 → k ⋅ B2.
15.3.3. GAINMIN and GAINMAX Parameters
GAINMIN and GAINMAX define the thresholds on the gain code outside which the fault “GAIN out of
Spec.” is set;
If GAINSATURATION is set, then the virtual gain code is saturated at GAINMIN and GAINMAX, and no
Diagnostic fault is set since the saturations applies before the Diag. check.