English
Language : 

MLX90367EDC-ABS Datasheet, PDF (19/36 Pages) Melexis Microelectronic Systems – TriaxisÒ Position Sensor IC feat. SENT
MLX90367
Triaxis® Position Sensor IC feat. SENT
The second part (positions 24 to 40) is optional as a whole enabled with EEPROM bit
EE_ExtendedSequence.
This second part consists of the error code (8 occurences), 8 OEM -defined Code
The temperature can be derived from SENT ID 23, TEMP sensor, with the following equation:
SENT@ ID 23 = 8 * (T[C] – 35[C]) + 865 lsb12
The accuracy of the actual Temperature is = ± 10 DegC.
14.3.3. Serial message sequence period
Sequence Length
(serial message count)
24
40
Sequence Length
(frame count)
432
720
Sequence Period
(ms, typical)
381
636
14.3.3.1. Error Code Rate
The Error Code are on purpose transmitted every second message, to maximize the rate, which equals
then 36 SENT frames.
14.3.4. Serial Message Error Code
The list of error and status messages transmitted in the 12-bit Enhanced Serial Message data field when
Enhance Serial Message ID is $01 is given in the following Table.
12 Bit Data
$000
$801
$808
$810
$820
$840
$880
$900
Diagnostic
No error
GainOOS
ADCSatura
ADCMonitor
VanaMoni
VddMoni
Rough Offset
TempMonitor
Comments
Front-end Gain code Out-of-spec (too low, too high)
Diag
ADC monitor
Analog Internal Supply Too Low
External Supply Too Low
Front-end Rough Offset too low, too high
Temperature Sensor monitor
In case multiple errors occur, then the resulting 12 bit enhanced serial message data will be the OR-operation of the
individual data values. Example $809 = GainOOS + ADCsatura
MLX90367
Rev 5.2
Page 19 of 36
Datasheet
Dec. 15, 15