14.3.1. MAPXYZ
The MAPXYZ parameter defines which fields are used to calculate the angle. The different possibilities
are described in the tables below.
This 2 bit value selects the first (B1) and second (B2) field components according the table below.
MAPXYZ
0 – 00b
1 – 01b
2 – 10b
3 – 11b
B1
B2
Angular
X
Y
XY mode
Zx
X
XZx mode
Y
Zx
YZx mode
Y
Zy
YZy mode
MAPXYZ = 3 is not recommended.
14.3.2. SMISM, k and SEL_k Parameters
(i) SMISM
When the mapping (B1=X, B2=Y) is selected, SMSIM defines the sensitivity mismatch factor that is
applied on B1, B2; When another B1, B2 mapping is selected, this parameter is “don’t care”.
This parameter is trimmed at factory; Melexis strongly recommends TO NOT over write it for optimal
performance.
(ii) k
When the mapping (B1=X, B2=Y) is NOT selected, k defines the sensitivity mismatch factor that is applied
on B1or B2 (according to parameter SEL_k – see below). When the mapping (B1=X, B2=Y) is selected,
this parameter is “don’t care”.
This parameter is trimmed at factory for mapping (B1=Z, B2=X). Melexis recommends to fine trim it when
a smaller linearity error (Le) is required and a different mapping than (B1=X, B2=Y) is selected.
(iii) SEL_k
When the mapping (B1=X, B2=Y) is NOT selected, SEL_k defines the component on which the sensitivity
mismatch factor k (see above): SEL_k = 0 means B1 k  B1 and SEL_k = 1 means B2  k  B2.
14.3.3. GAINMIN and GAINMAX Parameters
GAINMIN and GAINMAX define the thresholds on the gain code outside which the fault “GAIN out of
Spec.” is set;
If GAINSATURATION is set, then the virtual gain code is saturated at GAINMIN and GAINMAX, and no
Diagnostic fault is set since the saturations apply before the Diagnostic check.
MLX90366
Rev. 1.0
Page 24 of 34
Datasheet
25/Jun/13