English
Language : 

MLX90366 Datasheet, PDF (23/34 Pages) Melexis Microelectronic Systems – Triaxis Position Sensor Assembly feat. SENT
MLX90366
Triaxis Position Sensor Assembly feat. SENT
W
0 (0000b)
1
2
3
4
5
6
Range
360.0deg
320.0deg
288.0deg
261.8deg
240.0deg
221.5deg
205.7deg
x
22.5deg
20.0deg
18.0deg
16.4deg
15.0deg
13.8deg
12.9deg
7
192.0deg 12.0deg

W
Range
x
8
180.0deg 11.3deg
9
144.0deg 9.0deg
10 120.0deg 7.5deg
11 102.9deg 6.4deg
12
90.0deg 5.6deg
13
80.0deg 5.0deg
14
72.0deg 4.5deg
15
(1111b)
65.5deg
4.1deg
Outside of the selected range, the output will remain in clamping levels.
14.1.4. CLAMPING Parameters
The clamping levels are two independent values to limit the output voltage range. The CLAMPLOW
parameter adjusts the minimum output code. The CLAMPHIGH parameter sets the maximum output
code. Both parameters have 16 bits of adjustment and are available for both LNR modes.
14.2. Identification
Parameter
MELEXISID1
MELEXISID2
MELEXISID3
CUSTOMERID1
CUSTOMERID2
CUSTOMERID3
Value
0  65535
0  65535
0  65535
0  65535
0  65535
0  65535
Identification number: 48 bits (3 words) freely useable by Customer for traceability purpose.
14.3. Sensor Front-End
Parameter
MAPXYZ
SMISM
K
SEL_k
GAINMIN
GAINMAX
GAINSATURATION
Value
0 .. 3
0 .. 32768
0 .. 32768
0 or 1
0  41
0  41
0.. 1
MLX90366
Rev. 1.0
Page 23 of 34
Datasheet
25/Jun/13