Parameter
Symbol
Condition
Min Typ
Baseband Data Path
Data filter bandwidth
BDF depending on CF1,
CF2
Peak detector load current
IPKD
500
Start-up Parameters
Reference
start-up time
oscillator
tonRO
depending on crystal
parameters
350
Sequencer time
Receiver start-up time
tSEQ
tonRX
5504 / fREF
tonRO + tSEQ
200 250
0.6
Frequency Stability
Frequency pulling by supply
voltage
dfVCC
Max Unit
100
kHz
µA
650
µs
350
µs
1
ms
±3 ppm/V
4.5 External Components
Parameter
Crystal Parameters
Crystal frequency
Load capacitance
Static capacitance
Series resistance
Noise Cancellation Filter
Integrator capacitor
Clock Output
Pull-up resistor
Load capacitance
Symbol
Condition
f0
fundamental mode, AT
CL
C0
R1
CF3 depends on data rate
RCL
CL
Min
Max
Unit
16
27
MHz
10
15
pF
5
pF
60

12
nF
600

50
pF
39010 71121
Rev. 012
Page 24 of 29
Data Sheet