TH8055 Datasheet, PDF (1/20 Pages) Micro Electronics – Single Wire CAN Transceiver | |||
|
TH8055
Single Wire CAN Transceiver
Features and Benefits
 Fully compatible with J2411 Single Wire CAN specification for Class B in vehicle
communications
 30 µA typical power consumption in sleep mode independent from CAN voltage range
 Operating voltage range 5â¦18V
 Up to 100 kbps high-speed transmission mode
 Up to 40 kbps bus speed
 Selective BUS wakeup
 Low RFI due to output wave shaping
 Fully integrated receiver filter
 Bus terminals proof against short-circuits and transients in automotive environment
 Loss of ground protection
 Protection against load dump, jump start
 Thermal overload and short circuit protection
 ESD protection of 4 kV on CAN pin (2kV on any other pin)
 Undervoltage lock out
 Bus dominant timeout feature
Ordering Information
Ordering No.
TH8055 JDC
Temperature Range
-40 to 125 °C
Package
SOIC8
General Description
The TH8055 is a physical layer device for a single wire data link capable of operating with various CSMA/CR protocols
such as the Bosch Controller Area Network (CAN) version 2.0. This serial data link network is intended for use in
applications where high data rate is not required and a lower data rate can achieve cost reductions in both the physical
media components and in the microprocessor and/or dedicated logic devices which use the network.
The network shall be able to operate in either the normal data rate mode or a high speed data download mode for
assembly line and service data transfer operations. The high speed mode is only intended to be operational when the
bus is attached to an off-board service node. This node shall provide temporary bus electrical loads which facilitate
higher speed operation. Such temporary loads shall be removed when not performing download operations.
The bit rate for normal communications is typically 33 kbit/s, for high speed transmissions like described above a typical
bit rate of 83 kbit/s is recommended. The TH8055 is designed in accordance to the Single Wire CAN Physical Layer
Specification GMW3089 V1.26 and supports many additional features like undervoltage lockout, timeout for faulty
blocked input signals, output blanking time in case of bus ringing and a very low sleep mode current.
TH8055 - Datasheet
3901008055
Page 1 of 20
May 2004
Rev 005
|
▷ |