English
Language : 

MAX16000_12 Datasheet, PDF (8/26 Pages) Maxim Integrated Products – Low-Voltage, Quad-/Hex-/Octal-Voltage μP Supervisors
MAX16000–MAX16007
Low-Voltage, Quad-/Hex-/Octal-Voltage
µP Supervisors
Pin Description (MAX16003/MAX16004/MAX16005)
PIN
NAME
FUNCTION
1
1
3
2
2
4
3
3
5
4
5
7
5
6
8
6
7—
7
8—
8
9—
9 12 13
10 13 —
11 14 —
12 15 —
13 17 15
14 18 16
15 19 1
1
IN4 Monitored Input Voltage 4. See Table 1 for the input voltage threshold.
2
IN5 Monitored Input Voltage 5. See Table 1 for the input voltage threshold.
3
IN6 Monitored Input Voltage 6. See Table 1 for the input voltage threshold.
5
GND Ground
6
VCC Unmonitored Power-Supply Input
Output 4. When the voltage at IN4 falls below its threshold, OUT4 goes low and stays low
—
OUT4 until the voltage at IN4 exceeds its threshold. The open-drain output has a 30µA internal
pullup to VCC.
Output 5. When the voltage at IN5 falls below its threshold, OUT5 goes low and stays low
—
OUT5 until the voltage at IN5 exceeds its threshold. The open-drain output has a 30µA internal
pullup to VCC.
Output 6. When the voltage at IN6 falls below its threshold, OUT6 goes low and stays low
—
OUT6 until the voltage at IN6 exceeds its threshold. The open-drain output has a 30µA internal
pullup to VCC.
11
MARGIN Manual Deassert Input. Pull MARGIN low to deassert all outputs (go into high state),
regardless of the voltage at any monitored input.
Output 3. When the voltage at IN3 falls below its threshold, OUT3 goes low and stays low
—
OUT3 until the voltage at IN3 exceeds its threshold. The open-drain output has a 30µA internal
pullup to VCC.
Output 2. When the voltage at IN2 falls below its threshold, OUT2 goes low and stays low
—
OUT2 until the voltage at IN2 exceeds its threshold. The open-drain output has a 30µA internal
pullup to VCC.
Output 1. When the voltage at IN1 falls below its threshold, OUT1 goes low and stays low
—
OUT1 until the voltage at IN1 exceeds its threshold. The open-drain output has a 30µA internal
pullup to VCC.
13
IN1 Monitored Input Voltage 1. See Table 1 for the input voltage threshold.
14
IN2 Monitored Input Voltage 2. See Table 1 for the input voltage threshold.
15
IN3 Monitored Input Voltage 3. See Table 1 for the input voltage threshold.
8
Maxim Integrated