DS75LV Datasheet, PDF (7/13 Pages) Maxim Integrated Products – Digital Thermometer and Thermostat
Figure 4. O.S. OUTPUT Operation Example
In this example the DS75LV
is configured to have a fault
tolerance of 2.
TOS
Temperature
THYST
DS75LV: Digital Thermometer and Thermostat
Inactive
O.S. Output - Comparator Mode
Active
Inactive
O.S. Output - Interrupt Mode
Active
Assumes a read
has occurred
Conversions
CONFIGURATION REGISTER
The configuration register allows the user to program various DS75LV options such as conversion resolution,
thermostat fault tolerance, thermostat polarity, thermostat operating mode, and shutdown mode. The configuration
register is arranged as shown in Figure 5 and detailed descriptions of each bit are provided in Table 4. The user
has read/write access to all bits in the configuration register except the MSb, which is a reserved read-only bit. The
entire register is volatile, and thus powers–up in its default state.
Figure 5. Configuration Register
MSb
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
LSb
0
R1 R0 F1 F0 POL TM SD
7 of 13