English
Language : 

MAX1363 Datasheet, PDF (6/24 Pages) Maxim Integrated Products – 4-Channel, 12-Bit System Monitors with Programmable Trip Window and SMBus Alert Response
4-Channel, 12-Bit System Monitors with Programmable
Trip Window and SMBus Alert Response
ELECTRICAL CHARACTERISTICS (continued)
(VDD = 2.7V to 3.6V (MAX1363), VDD = 4.5V to 5.5V (MAX1364), VREF = 2.048V (MAX1363), VREF = 4.096V (MAX1364), CREF =
0.1µF, fSCL = 1.7MHz, TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.)
Note 1: Devices configured for unipolar single-ended inputs.
Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the gain and offset have
been calibrated.
Note 3: Offset nulled.
Note 4: Conversion time is defined as the number of clock cycles needed for conversion multiplied by the clock period.
Conversion time does not include acquisition time. SCL is the conversion clock in the external clock mode.
Note 5: The throughput rate of the I2C bus is limited to 94.4ksps. The MAX1363/MAX1364 can perform conversions up to 133ksps
in monitor mode when not reading back results on the I2C bus.
Note 6: A filter on the SDA and SCL inputs suppresses noise spikes and delays the sampling instant.
Note 7: The absolute input-voltage range for the analog inputs (AIN0–AIN3) is from GND to VDD.
Note 8: When the internal reference is configured to be available at AIN3/REF (SEL[2:1] = 11), decouple AIN3/REF to GND with a
0.01µF capacitor.
Note 9: ADC performance is limited by the converter’s noise floor, typically 300µVP-P.
Note 10: Maximum conversion throughput in internal clock mode when the data is not clocked out.
Note 11: For the MAX1363, PSRR is measured as
[ ] ⎡
⎢
⎢
⎣
VFS (3.6V) − VFS (2.7V)
×
2N − 1⎤⎥
VREF
⎥
⎦
(3.6V − 2.7V)
and for the MAX1364, PSRR is measured as
[ ] ⎡
⎢
⎢
⎣
VFS (5.5V) − VFS (4.5V)
×
2N − 1⎤⎥
VREF
⎥
⎦
(5.5V − 4.5V)
Note 12: CB = total capacitance of one bus line in pF.
Note 13: fSCLH must meet the minimum clock low time plus the rise/fall times.
Note 14: A master device must provide a data hold time for SDA (referred to VIL of SCL) to bridge the undefined region of SCL’s
falling edge.
Typical Operating Characteristics
(VDD = 3.3V (MAX1363), VDD = 5V (MAX1364), fSCL = 1.7MHz, external clock, fSAMPLE = 94.4ksps, single-ended, unipolar,
TA = +25°C, unless otherwise noted.)
DIFFERENTIAL NONLINEARITY
vs. DIGITAL CODE
0.5
0.4
0.3
0.2
0.1
0
-0.1
-0.2
-0.3
-0.4
-0.5
0
500 1000 1500 2000 2500 3000 3500 4000
DIGITAL OUTPUT CODE
INTEGRAL NONLINEARITY
vs. DIGITAL CODE
1.0
0.8
0.6
0.4
0.2
0
-0.2
-0.4
-0.6
-0.8
-1.0
0 500 1000 1500 2000 2500 3000 3500 4000
DIGITAL OUTPUT CODE
FFT PLOT
-60
fSAMPLE = 94.4ksps
fIN = 10kHz
-80
-100
-120
-140
-160
-180
0
10
20
30
40
50
FREQUENCY (kHz)
6 _______________________________________________________________________________________