400ksps/300ksps, Single-Supply, Low-Power,
Serial 10-Bit ADCs with Internal Reference
TIMING CHARACTERISTICS—MAX1084
(Figures 1, 2, 8, 9; VDD = +4.5V to +5.5V, TA = TMIN to TMAX, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
SCLK Period
tCP
SCLK Pulse Width High
SCLK Pulse Width Low
CS Fall to SCLK Rise Setup
SCLK Rise to CS Rise Hold
SCLK Rise to CS Fall Ignore
CS Rise to SCLK Rise Ignore
tCH
tCL
tCSS
tCSH
tCSO
tCS1
SCLK Rise to DOUT Hold
SCLK Rise to DOUT Valid
CS Rise to DOUT Disable
CS Fall to DOUT Enable
CS Pulse Width High
tDOH
tDOV
tDOD
tDOE
tCSW
CLOAD = 20pF
CLOAD = 20pF
CLOAD = 20pF
CLOAD = 20pF
MIN TYP MAX UNITS
156
ns
62
ns
62
ns
35
ns
0
ns
35
ns
35
ns
10
ns
80
ns
10
65
ns
65
ns
100
ns
TIMING CHARACTERISTICS—MAX1085
(Figures 1, 2, 8, 9; VDD = +2.7V to +3.6V, TA = TMIN to TMAX, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
SCLK Period
SCLK Pulse Width High
SCLK Pulse Width Low
CS Fall to SCLK Rise Setup
SCLK Rise to CS Rise Hold
SCLK Rise to CS Fall Ignore
CS Rise to SCLK Rise Ignore
SCLK Rise to DOUT Hold
SCLK Rise to DOUT Valid
CS Rise to DOUT Disable
CS Fall to DOUT Enable
CS Pulse Width High
tCP
tCH
tCL
tCSS
tCSH
tCSO
tCS1
tDOH
tDOV
tDOD
tDOE
tCSW
CLOAD = 20pF
CLOAD = 20pF
CLOAD = 20pF
CLOAD = 20pF
CLOAD = 20pF
MIN TYP MAX UNITS
208
ns
83
ns
83
ns
45
ns
0
ns
45
ns
45
ns
13
ns
100
ns
13
85
ns
85
ns
100
ns
Note 1: Tested at VDD = VDD,MIN.
Note 2: Relative accuracy is the deviation of the analog value at any code from its theoretical value after the full-scale range has
been calibrated.
Note 3: Internal reference, offset, and reference errors nulled.
Note 4: Conversion time is defined as the number of clock cycles multiplied by the clock period; clock has 50% duty cycle.
Note 5: External load should not change during conversion for specified accuracy. Guaranteed specification limit of 2mV/mA due to
production test limitation.
Note 6: Electrical characteristics are guaranteed from VDD,MIN to VDD,MAX. For operations beyond this range, see Typical Operating
Characteristics.
Note 7: MAX1084 tested with 20pF on DOUT and fSCLK = 6.4MHz, 0 to 5V. MAX1085 tested with same loads, fSCLK = 4.8MHz, 0 to
3V. DOUT = full scale.
_______________________________________________________________________________________ 5