English
Language : 

MAX13256 Datasheet, PDF (3/17 Pages) Maxim Integrated Products – 36V H-Bridge Transformer Driver for Isolated Supplies Integrated System Protection
MAX13256
36V H-Bridge Transformer
Driver for Isolated Supplies
ELECTRICAL CHARACTERISTICS (continued)
(VDD = 8V to 36V, VEN = 0V, TA = -40NC to +125NC, unless otherwise noted. Typical values are at TA = +25NC.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX
ST1, ST2 Current Limit
ILIM
RLIM = 1000I
RLIM = 3010I
500 650 800
165 215 265
ST1, ST2 Leakage Current
ILKG
LOGIC SIGNALS (CLK, EN, FAULT)
VEN = 3.3V, VCLK = 0V,
VST1 = VST2 = 0V or VDD
-1
+1
Input Logic-High Voltage
Input Logic-Low Voltage
Input Leakage Current
FAULT Output Logic-Low
Voltage
VIH
VIL
IIL
VCLK = VEN = 5.5V or 0V
VOL
IFAULT = 10mA
2
0.8
-1
+1
1
FAULT Leakage Current
ILKGF
VFAULT = 36V, FAULT deasserted
10
AC CHARACTERISTICS
Switching Frequency
fSW
VCLK = 0V, measured at ST1/ST2 outputs
255
425
700
CLK Input Frequency
ST1/ST2 Duty Cycle
fEXT
External clocking
DTC
Internal or external clocking
200
2000
49
50
51
ST1/ST2 Rise Time
tRISE
ST1/ ST2 = 20% to 80% of VDD, RL = 1kI,
CL = 50pF, Figure 1a
100
ST1/ST2 Fall Time
tFALL
ST1/ST2 = 80% to 20% of VDD, RL = 1kI,
CL = 50pF, Figure 1a
100
Crossover Dead Time
Watchdog Timeout
Current-Limit Blanking Time
Current-Limit Autoretry Time
PROTECTION
tDEAD
tWDOG
tBLANK
tRETRY
RL = 200I, Figure 1b
Figure 2
Figure 2
30
20
32
55
0.73 1.2
2.0
23.4 38.4 64.0
Thermal-Shutdown Threshold
Thermal-Shutdown Hysteresis
TSHDN
TSHDN_HYS
+160
10
Note 2: All units are production tested at TA = +25NC. Specifications over temperature are guaranteed by design.
Note 3: If VDD is greater than 27V, see the Snubber section.
UNITS
mA
FA
V
V
FA
V
FA
kHz
kHz
%
ns
ns
ns
Fs
ms
ms
NC
NC
����������������������������������������������������������������� Maxim Integrated Products   3