ABSOLUTE MAXIMUM RATINGS
(All voltages referenced to GND.)
Voltage Range on VCC, ALARM, SDA, SCL.........-0.5V to +6.0V
Voltage Range on EVENT......................... -0.5V to (VCC + 0.5V),
not to exceed +6.0V
Continuous Power Dissipation (TA = +70NC)
SO (derate 5.9mW/NC above +70NC)........................470.6mW
Maximum Junction Temperature......................................+150NC
Operating Temperature Range........................... -40NC to +85NC
Programming Temperature Range........................ 0NC to +70NC
Storage Temperature Range............................. -55NC to +150NC
Lead Temperature (soldering, 10s).................................+300NC
Soldering Temperature (reflow).......................................+260NC
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional opera-
tion of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
(TA = -40NC to +85NC, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
Supply Voltage
Input Logic 1 (SCL, SDA)
Input Logic 0 (SCL, SDA)
VCC
VIH
VIL
(Note 1)
EVENT Input Trip Point
VETP
EVENT Trip Point Hysteresis
Power-On Reset
VHYS
VPOR
MIN TYP MAX
2.5
5.5
0.7 x VCC
VCC + 0.3
-0.3
0.3 x VCC
0.3 x 0.5 x 0.7 x
VCC
VCC
VCC
1% of VCC
2.4
UNITS
V
V
V
V
V
DC ELECTRICAL CHARACTERISTICS
(VCC = 2.5V to 5.5V, TA = -40NC to +85NC, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
Input Leakage
ALARM Output (IOL = 10mA)
SDA Output (IOL = 4mA)
Active Supply Current
EEPROM Write Current
ILI
VOL
VOL
ICCA
IEE
(Note 1)
(Note 1)
MIN TYP MAX UNITS
-1
+1
FA
0.8
V
0.4
V
180 300
FA
250 350
FA
EVENT TIMING
(VCC = 2.5V to 5.5V, TA = -40NC to +85NC, unless otherwise noted.)
PARAMETER
SYMBOL
CONDITIONS
Time Event Minimum
Time Event Increment
Time Event Max
CLR ALM to Alarm Set
tG
(Note 1)
tEI
(Note 1)
tEM
(Note 2)
(Note 2)
MIN
10
237.5
10
TYP
35
250
MAX
70
262.5
34
150
UNITS
ms
ms
Years
Fs