English
Language : 

MAX1061 Datasheet, PDF (18/20 Pages) Maxim Integrated Products – 250ksps, +3V, 8-/4-Channel, 10-Bit ADCs with +2.5V Reference and Parallel Interface
250ksps, +3V, 8-/4-Channel, 10-Bit ADCs
with +2.5V Reference and Parallel Interface
1
23
4
5
6
78
9 10 11 12 13 14 15 16
CLK
WR
RD
HBEN
CONTROL
D7–D0 BYTE
D7–D0 D9–D8
LOW HIGH
BYTE BYTE
STATE
ACQUISITION
SAMPLING INSTANT
Figure 10. Timing Diagram for Fastest Conversion
CONTROL BYTE
CONVERSION
D7–D0 D9–D8
LOW HIGH
BYTE BYTE
ACQUISITION
Total Harmonic Distortion
Total harmonic distortion (THD) is the ratio of the RMS
sum of the first five harmonics of the input signal to the
fundamental itself. This is expressed as:
( ) THD
=
20 x
log
⎛
⎝⎜
V22 + V32 + V42 + V52 / V1⎞⎠⎟
where V1 is the fundamental amplitude, and V2 through
V5 are the amplitudes of the 2nd- through 5th-order har-
monics.
Spurious-Free Dynamic Range
Spurious-free dynamic range (SFDR) is the ratio of the
RMS amplitude of the fundamental (maximum signal
component) to the RMS value of the next-largest distor-
tion component.
SUPPLIES
+3V
VLOGIC = +2V/+3V GND
R* = 5Ω
4.7µF
0.1µF
VDD
GND
COM
+2V/+3V DGND
MAX1061
MAX1063
DIGITAL
CIRCUITRY
*OPTIONAL
Figure 11. Power-Supply and Grounding Connections
18 ______________________________________________________________________________________