English
Language : 

MAX11359A Datasheet, PDF (12/66 Pages) Maxim Integrated Products – 16-Bit Data-Acquisition System with ADC, DAC, UPIOs, RTC, Voltage Monitors, and Temp Sensor
16-Bit Data-Acquisition System with ADC, DAC,
UPIOs, RTC, Voltage Monitors, and Temp Sensor
TIMING CHARACTERISTICS (Figures 1 and 19)
(AVDD = DVDD = +1.8V to +3.6V, external VREF = +1.25V, CLK32K = 32.768kHz (external clock), CREG = 10µF, CCPOUT = 10µF,
10µF between CF+ and CF-, TA = TMIN to TMAX, unless otherwise noted. Typical values are at TA = +25°C.) (Note 1)
PARAMETER
SCLK Operating Frequency
SCLK Cycle Time
SCLK Pulse-Width High
SCLK Pulse-Width Low
DIN to SCLK Setup
DIN to SCLK Hold
SCLK Fall to DOUT Valid
CS Fall to Output Enable
CS Rise to DOUT Disable
CS to SCLK Rise Setup
CS to SCLK Rise Hold
SYMBOL
fSCLK
tCYC
tCH
tCL
tDS
tDH
tDO
tDV
tTR
tCSS
tCSH
CONDITIONS
CL = 50pF, Figure 2
CL = 50pF, Figure 2
CL = 50pF, Figure 2
MIN TYP MAX UNITS
0
10
MHz
100
ns
40
ns
40
ns
30
ns
0
ns
40
ns
48
ns
48
ns
20
ns
0
ns
DVDD Monitor Timeout Period
tDSLP (Note 16)
1.5
s
Wake-Up (WU) Pulse Width
tWU
Minimum pulse width required to detect a
wake-up event
1
µs
Shutdown Delay
tDPU
The delay for SHDN to go high after a valid
wake-up event
1
µs
HFCK Turn-On Time
tDFON
The turn-on time for the high-frequency
clock and FLL (FLLE = 1) (Note 17)
If FLLE = 0, the turn-on time for the high-
frequency clock (Note 18)
10
ms
10
µs
CRDY to INT Delay
HFCK Disable Delay
SHDN Assertion Delay
The delay for CRDY to go low after the
tDFI
HFCK clock output has been enabled
(Note 19)
7.82
ms
The delay after a shutdown command has
tDFOF asserted and before HFCK is disabled
1.95
ms
(Note 20)
tDPD (Note 21)
2.93
ms
Note 16: The delay for the sleep voltage monitor output, RESET, to go high after VDD rises above the reset threshold. This is largely
driven by the startup of the 32kHz oscillator.
Note 17: It is gated by an AND function with three inputs—the external RESET signal, the internal DVDD monitor output, and the
external SHDN signal. The time delay is timed from the internal LOVDD going high or the external RESET going high,
whichever happens later. HFCK always starts in the low state.
Note 18: If FLLE = 0, the internal signal CRDY is not generated by the FLL block and INT or INT are deasserted.
Note 19: CRDY is used as an interrupt signal to inform the µC that the high-frequency clock has started. Only valid if FLLE = 1.
Note 20: tDFOF gives the µC time to clean up and go into sleep-override mode properly.
Note 21: tDPD is greater than the HFCK delay for the MAX11359A chip to clean up before losing power.
12 ______________________________________________________________________________________