MODEL NUMBER
RIGID SINGLE ROD PROBE FOR
(FOR IN-TANK MOUNTING ONLY)
• 316/316L (1.4401/1.4404) material for standard applications
• Hastelloy C (2.4819) or Monel (2.4360) for extreme aggressive media
• PFA insulated for applications with excessive coating / buildup.
LIQUIDS
Models available for quick shipment, usually within one
week after factory receipt of a complete purchase order,
through the Expedite Ship Plan (ESP).
BASIC MODEL NUMBER
7 * F Standard single rod GWR probe
7 * J High temperature / high pressure single rod GWR probe
*Specify “E” for English (e.g., 7EF) or “M” for Metric (e.g., 7MF)
εr ≥ 1.9/10 Œ
εr ≥ 1.9/10 Œ
MATERIAL OF CONSTRUCTION
A 316/316L (1.4401/1.4404) stainless steel
B Hastelloy C (2.4819)
C Monel (2.4360)
J 316/316L SS NACE Construction
4 PFA insulated 316/316L (1.4401/1.4404) stainless steel (for 7xF only)
PROCESS CONNECTION – SIZE/TYPE
Threaded
4 1 2" NPT thread
4 2 2" BSP (G2) thread
ANSI Flanges 
4 3 2"
150# ANSI RF
4 4 2"
300# ANSI RF
4 5 2"
600# ANSI RF
4 K 2"
600# ANSI RJ
4 M 2"
900/1500# ANSI RJ
5 3 3"
150# ANSI RF flange
5 4 3"
300# ANSI RF flange
5 5 3"
600# ANSI RF flange
5 K 3"
600# ANSI RJ flange
5 L 3"
900# ANSI RJ flange
5 M 3"
1500# ANSI RJ flange
6 3 4"
150# ANSI RF flange
6 4 4"
300# ANSI RF flange
6 5 4"
600# ANSI RF flange
6 K 4"
600# ANSI RJ flange
6 L 4"
900# ANSI RJ flange
6 M 4"
1500# ANSI RJ flange
EN/DIN Flanges 
D A DN 50, PN 16 EN 1092-1 Type A
D B DN 50, PN 25/40 EN 1092-1 Type A
D D DN 50, PN 63 EN 1092-1 Type B2
D E DN 50, PN 100 EN 1092-1 Type B2
D F DN 50, PN 160 EN 1092-1 Type B2
D G DN 50, PN 250 EN 1092-1 Type B2
E A DN 80, PN 16 EN 1092-1 Type A
E B DN 80, PN 25/40 EN 1092-1 Type A
E D DN 80, PN 63 EN 1092-1 Type B2
E E DN 80, PN 100 EN 1092-1 Type B2
E F DN 80, PN 160 EN 1092-1 Type B2
E G DN 80, PN 250 EN 1092-1 Type B2
F A DN 100, PN 16 EN 1092-1 Type A
F B DN 100, PN 25/40 EN 1092-1 Type A
F D DN 100, PN 63 EN 1092-1 Type B2
F E DN 100, PN 100 EN 1092-1 Type B2
F F DN 100, PN 160 EN 1092-1 Type B2
F G DN 100, PN 250 EN 1092-1 Type B2
PROCESS SEAL – O-RING MATERIAL
For 7xF
0 Viton® GFLT seal: for universal use
-40° F (-40° C) / +300° F (+150° C)
2 Kalrez 4079 seal: for aggressive media -40° F (-40° C) / +300° F (+150° C)
8 Aegis PF 128 seal: for aggressive media -20° C (-4° F) / +300° F (+150° C)
For 7xJ
8 PEEK/Aegis PF 128 seal -0° F (-15° C) / +600° F (+315° C)
Consult factory for alternative o-ring materials. For Ammonia/Chlorine applications, use the
7xD GWR probe. Viton® is a registered trademark of DuPont Performance Elastomers.
INSERTION LENGTH
24 to 240 inches (60 to 610 cm)
(unit of measure is determined by second digit of Model Number)
Examples: 24 inches = 024; 60 centimeters = 060
Œ For dielectric range ≤1.9 and 10, probe must be mounted
within 2–6 inches (50–150 mm) distance from the tank wall or
in a cage or bridle. See mounting consideration on page 25.