AGENCY APPROVALS
AGENCY
FM
CSA
IEC
ATEX
MODEL APPROVED
705-5XXX-1XX
705-5XXX-2XX
705-5XXX-3XX
705-5XXX-4XX
705-5XXX-XXX
705-5XXX-XXX
705-5XXX-1XX
705-5XXX-2XX
705-5XXX-3XX
705-5XXX-4XX
705-5XXX-XXX
705-5XXX-XXX
705-5XXX-AXX
705-5XXX-BXX
705-5XXX-AXX
705-5XXX-BXX
705-5XXX-CXX
705-5XXX-DXX
705-51XX-EXX
705-51XX-FXX
705-52XX-EXX
705-52XX-FXX
APPROVAL CATEGORY
Intrinsically Safe
Explosion Proof Œ
(with Intrinsically Safe probe)
Non-Incendive
Suitable for: 
Intrinsically Safe
Explosion Proof Œ
(with Intrinsically Safe probe)
Non-Incendive
Suitable for: 
Intrinsically Safe Ž
APPROVAL CLASSES
Class I, Div. 1; Groups A, B, C, & D
Class II, Div. 1; Groups E, F, & G T4
Class III, Type 4X, IP66
Entity
Class I, Div. 1; Groups B, C & D
Class II, Div. 1; Groups E, F, & G T4
Class III, Type 4X, IP66
Class I, Div. 2; Groups A, B, C, & D
Class II, Div. 2; Groups F & G T4
Class III, Type 4X, IP66
Class I, Div. 1; Groups A, B, C, & D
Class II, Div. 1; Group E, F & G T4
Class III, Type 4X
Entity
Class I, Div. 1; Groups B, C & D
Class II, Div. 1; Group E, F & G T4
Class III, Type 4X
Class I, Div. 2; Groups A, B, C, & D
Class II, Div. 2; Group E, F & G T4
Class III, Type 4X
Zone 0 Ex ia IIC T4
Intrinsically Safe Ž
II 1G, EEx ia IIC T4
Flame Proof
II 1/2G, EEx d [ia] IIC T6
Non-sparking
II 3(1)G, EEx nA [ia] IIC T4..T6
with probe II 1 G EEx ia IIC T6
II 3(1)G, EEx nA [nL] [ia] IIC T4..T6
with probe II 1 G EEx ia IIC T6
0344
These units are in conformity of:
1. The EMC Directive: 2004/108/EC. The units have
been tested to EN 61326.
2. Directive 94/9/EC for equipment or protective system
for use in potentially explosive atmospheres.
Note: Single and twin rod probes must be used in metallic
vessel or stillwell to maintain CE compliance.
ΠFactory Sealed: This product has been approved by Factory Mutual Research (FM), and Canadian
Standards Association (CSA), as a Factory Sealed device.
 IMPORTANT: Measured media inside vessel must be non-flammable only.
If media inside vessel is flammable, then the explosion proof version (which
contains an internal barrier making the probe Intrinsically Safe) is required.
Ž Special conditions for safe use
Because the enclosure of the Guided Wave Radar Level Transmitter Eclipse Model 705-5 _ _ _ - _1_
and/or Probe Eclipse Model 7_ _ - _ _ _ _ - _ _ _ is made of aluminum, if it is mounted in an area
where the use of category 1 G (Zone 0) apparatus is required, it must be installed such, that, even
in the event of rare incidents, ignition sources due to impact and friction sparks are excluded.
For applications in explosive atmospheres caused by gases, vapours or mists and where category
1G (Zone 0) apparatus is required, electrostatic charges on the non-metallic parts of the Probe
Eclipse Model 7x5- _ _ _ _ - _ _ _ , Model 7x7- _ _ _ _ - _ _ _ and Model 7_ F- _ _ _ _ - _ _ _ shall be avoided.
13