3-1461491-5 Datasheet, PDF (9/40 Pages) Tyco Electronics – Qualification Test Report | |||
|
◁ |
Qualification Test Report
501-79817
ï¼ï¼è©¦é¨æ¡ä»¶
1.Test conditions
1-1.ã試é¨ãªã¬ã¼
1-1.Sample
1-2.ã測å®ç®æ
1-2.Test parts
1-3.ã測å®æ¡ä»¶
1-3.Measurement conditions
1-4.ãå¨å²æ¸©åº¦
1-4.Ambient temperature
1-5.ã試ãããæ
1-5.Amount of asmple
1-6.ã試é¨è£
ç½®
1-6.Measurement instrument
èé»å§éç試é¨
Dielectric voltage withstanding test
è³-45628
Data No.:45628
ï¼ãPCNï¼ï¼¤ï¼ï¼ ã¿ã¤ã
;PCN-D3M TYPE
ï¼ãï¼ï¼ï¼å極æ¥ç¹é
;(1)between open contacts
ããï¼ï¼ï¼ã³ã¤ã«ï¼æ¥ç¹éï¼å¯å端åã¨åºå®ç«¯åç絡ï¼
;(2)between coil to contact
ï¼ãï¼ï¼ï¼¨ï½ï¼åç¨é»æºæ³¢å½¢ï¼
;50Hz
ããå¾ææ³ã«ããï¼ãªã¼ã¯æ¤ç¥é»æµãï¼ãï¼ï½Aï¼
;by gradually rise up method (Leak current : 1mA)
ï¼ã常温ï¼ç¹ã«ç©ºèª¿ããã¦ããªãé°å²æ°ï¼
;Standard atmospheric conditions
ï¼ãï½ï¼ï¼ï¼
;n=10
ï¼ãèå§è©¦é¨å¨ï¼ï¼´ï¼¯ï¼³ï¼ï¼ï¼ï¼ï¼ï¼´ï¼¯ï¼³ï¼ï¼ï¼ï¼ï¼
;Withstanding Voltage Tester(TOS5051, TOS8700)
ï¼ï¼ãã¼ã¿
2.Data
2-1.ãå極æ¥ç¹éï¼VAC)
2-1.between open contacts (VAC)
ãªã¬ã¼NO. NGé»å§
Relay No. NG voltage
1
1,620
2
1,460
3
1,700
4
1,830
5
1,580
6
1,640
7
1,710
8
1,590
9
1,620
10
1,720
å¹³å
Average
1,647
2-2.ãã³ã¤ã«ï¼æ¥ç¹éï¼VAC)
2-2.between coil to contact (VAC)
ã³ã¤ã«ç«¯å-å¯å端å
ã³ã¤ã«ç«¯å-åºå®ç«¯å
Coil - Movable terminal
Coil - Stationary terminal
ãªã¬ã¼NO. NGé»å§
ãªã¬ã¼NO. NGé»å§
Relay No. NG voltage
Relay No. NG voltage
1
4,890
1
5,030
2
4,920
2
4,780
3
5,600
3
4,640
4
5,250
4
4,890
5
5,440
5
5,000
6
4,920
6
4,920
7
5,210
7
4,860
8
5,460
8
4,880
9
5,120
9
4,930
10
4,710
10
5,020
å¹³å
Average
5,152
å¹³å
Average
4,895
ï¼ï¼ãçµããæ
3.Result
ããã ãå極æ¥ç¹éACï¼ï¼ï¼V ï¼åéãã³ã¤ã«ï¼æ¥ç¹éACï¼,ï¼ï¼ï¼Vï¼åéã¯ååä¿è¨¼ã§ããã¨
å¤å®ãã¾ãã
We could judge that limit values of these relay's withstanding voltage
AC750V for 1 minute (open contacts) and AC4,000V for 1 minute (between coil to contact)
under above test conditions.
Rev. A1
9 of 40
|
▷ |