3-1461491-5 Datasheet, PDF (15/40 Pages) Tyco Electronics – Qualification Test Report | |||
|
◁ |
Qualification Test Report
501-79817
温度ä¸æç¹æ§
Temperature rise test
â
¡ï¼æ¥ç¹æ¸©åº¦ä¸æï¼æ¸©åº¦è¨æ³ï¼
â
¡.Contact temperature rise test
ï¼ï¼è©¦é¨æ¡ä»¶
1.test conditions
1-1.試é¨ãªã¬ã¼ããããã
ï¼ï¼°ï¼£ï¼®-D3M ã¿ã¤ãï¼å®æ ¼æ¶è²»é»åï¼ï¼ï¼ï¼ï¼ï¼·ï¼
1-1.Sample
1-2.æä½é»å§
;PCN-D3M TYPE (electricity : 0.12W)
ï¼å®æ ¼é»å§
1-2.Operate voltage
1-3.æ¥ç¹éé»é»æµ
;Rated voltage
ï¼ï¼¤ï¼£ï¼ï¼¡ï¼ï¼ï¼¡ï¼ï¼ï¼¡
1-3.Load
1-4.éé»æé
;DC0A, 3A, 5A
ï¼1æé
1-4.Tesr time
1-5.å¨å²æ¸©åº¦
1-5.Ambient temperature
1-6.試ãããæ
;1 hour
ï¼å¸¸æ¸©ï¼ç¹ã«ç©ºèª¿ãã¦ããªãé°å²æ°ï¼
;Standard atmospheric conditions
ï¼ï½ï¼ï¼
1-6.Amount of asmple
1-7.試é¨è£
ç½®
;n=3
ï¼ã³ã¤ã«æä½ï¼PMC35â1ãæ¥ç¹éé»ï¼GP035â20
1-7.Measurement instrument
;Coil operation : PMC35-1, Contact load : GP035-20
ã温度è¨é²ï¼HYBRID RECORDERãDR-130
ï¼ï¼ãã¼ã¿
Thermo Recoder : HYBRID RECORDER DR-130
2.Data
è³-45632-2
Data No.:45632-2
[K]
100
æ¥ç¹æ¸©åº¦ä¸æ
Contact temperature rise test
90
80
70
60
50
40
30
20
ï¼ï¼¡
ï¼ï¼¡
10
0
0
5
10
15
20
25
30
35
40
é»æµï¼©2[A] (Current)
Rev. A1
15 of 40
|
▷ |