Qualification Test Report
501-79817
æ¬å ±åæ¸ã¯ããªã¬ã¼ã®é»æ°çãæ©æ¢°çåã³ç°å¢çæ§è½å¿
è¦æ¡ä»¶ã«ã¤ãã¦è¡ãªã£ã試é¨å
容ã
è¨è¿°ãã¦ãã¾ãã
This report covers the electrical, mechanical and environmental performance requirements of the Relay.
æ¬å ±åæ¸ã®ä¸è¬ç¹æ§åå¸ã¯ãPCN-112D3M ã®ç¹æ§åå¸å
容ãè¨è¿°ãã¦ãã¾ãã
A general characteristic of this report describes the content of PCN-112D3M.
1.3 çµè«
Conclusion
å½ãªã¬ã¼ã¯ã該å½ã®è£½åè¦æ ¼ 108-79817 Rev. A ã®æ§è½å¿
è¦æ¡ä»¶ã«åè´ãã¦ãã¾ãã
This relay meets the electrical, mechanical and environmental performance requirements of Product Specification,
108-79817, Rev. A.
1.4 試 æ
Test Samples
試æã¯ç¾è¡ã®çç£ã·ã¹ãã ããç¡ä½çºæ½åºæ³ã«ããåãåºããã¾ããã
Samples were taken randomly from current production. The following samples were used:
1.5 æ示ç¡ãå ´åã¯æ¨æºç¶æ
ã§è©¦é¨ãè¡ããã¾ããã
An examination was done under the standard condition in the case without directions.
1.6 æ¨æºç¶æ
STANDARDS TEST CONDITION
温度
20±5â
TEMPERATURE
湿度
60±10%
HUMIDITY
測å®æ¡ä»¶
端åãä¸ã¨ããæ¹åãæ¨æºã¨ãã。
DIRECTON OF MEASUREMENT
Terminals down position is standard position.
Rev. A1