408-8980 Datasheet, PDF (8/8 Pages) Tyco Electronics – These instructions cover the installation and use of the kits listed in the table in Figure 1.
Electronic Applicator Counter Assembly Kit(s)
408-8980
released and no communication link has been
established.
On the test display, all segments of the display are
turned on (Figure 17). This display is used to
determine if a segment is malfunctioning.
Low Battery
Icon
Serial Number Icon
Alarm Icon
Input/Out Icon
Infrared Communication Icon
Figure 17
The software version indicates what version of
software was programmed into the counter.
applicators and the right switch is selected for
end–feed type mechanical applicators.
When in the Switch Selection mode, the switch state
indicators will flash.
Pressing the button will result in the left switch, the
right switch, or both switches being selected. After the
desired switch has selected, stop pressing the button
and the counter will revert back to the Switch State
mode in 15 seconds.
When in the Switch State mode, the counter will
return to the Sleep mode 15 seconds after the
pushbutton is released unless switch activity is
detected. It will return to the Sleep mode after 60
switch state changes.
If, while in the Switch State mode, the button is
pressed again, the counter will cycle back to the Total
Count mode.
4.4. Switch State Mode/Switch Selection Mode
If the pushbutton is pressed a fourth time, the state of
the reed switches and the Input/Output icon are
displayed (Figure 18).The switch is closed when the
ring magnet is in close proximity of the reed switch.
Input/Output Icon
Display Indicates that the Left Reed Switch
is Closed, and the Right Reed Switch Is Open.
Figure 18
If the pushbutton is held down for three seconds, the
counter is put in the Switch Selection mode
(Figure 19). The operator uses this mode to select
which reed switch to use for sensing the ring magnet.
NOTE
i
NOTE
i
If the counter detects that the battery is low, the
low battery icon will be displayed when the
display is turned on. The battery is not
replaceable. The counter will need to be
replaced.
If the target count for an alarm counter has been
exceeded, the alarm icon will be displayed when
the display is turned on. Alarm counts are created
and target counts are set using the Electronic
Applicator Counter Software.
5. CLEANING
The counter may be submerged for cleaning in up to
12 inches of commercial non–flammable cleaning
solvents for 20 minutes.
DANGER
To prevent personal injury, replace the counter
immediately if the plastic case becomes cracked.
Although the counter has been sealed, cracks or
leaks could expose the internal battery to
flammable liquid resulting in the possibility of fire,
or explosion. DO NOT SUBMERGE THE
COUNTER IN A FLAMMABLE LIQUID.
Display Indicates that the Right Reed Switch is Selected.
The Gray Segments Would Be Flashing.
6. REVISION SUMMARY
Since the previous release of this instruction sheet,
the document format was updated and the logo was
changed.
Display Indicates that the Left Reed Switch is Selected.
The Gray Segments Would Be Flashing.
Figure 19
Only one switch should be selected. Typically, the left
switch is selected for side–feed type mechanical
8 of 8