English
Language : 

MA4SW110 Datasheet, PDF (5/8 Pages) Tyco Electronics – Monolithic PIN Diode Switches
Monolithic Pin Diode Switches
MA4SW110, MA4SW210, MA4SW310
V5.00
Operation of the MA4SW Series
Operation of the MA4SW series of PIN Switches is
achieved by simultaneous application of negative DC
current to the low loss switching arm J1, J2, or J3, and
positive DC current to the remaining switching arms as
shown in the Bias Connection circuits. DC return is
achieved via J1. The control currents should be supplied
by constant current sources. The voltages at these points
will not exceed + 1.5 volts (1.2 volts typical) at currents up
to + 50 mA. In the Low Loss state, the series diode must
be forward biased and the shunt diode reverse biased. In
the isolated arm, the shunt diode is forward biased and the
series diode is reverse biased.
Driver Connections
MA4SW110
Control Level
(DC Current) at
J2
-20 mA
+20 mA
Condition of
RF Output
J1-J2
Low Loss
Isolation
MA4SW210
Control Level
(DC Current) at
J2
-20 mA
+20 mA
J3
+20 mA
-20 mA
Condition
of RF
Output
J1-J2
Low Loss
Isolation
Condition of
RF Output
J1-J3
Isolation
Low Loss
MA4SW310
Control Level (DC Current) at
J2
-20 mA
+20 mA
+20 mA
J3
+20 mA
-20 mA
+20 mA
J4
+20 mA
+20 mA
-20 mA
Condition
of RF
Output
J1-J2
Low Loss
Isolation
Isolation
Conditio
n of RF
Output
J1-J3
Isolation
Low Loss
Isolation
Condition
of RF
Output
J1-J4
Isolation
Isolation
Low Loss
Handling Considerations
Cleanliness: These chips should be handled in a clean
environment.
Electro-Static Sensitivity: The MA4SW Series PIN
switches are ESD, Class 1 sensitive. The proper ESD
handling procedures should be used.
MA4SW110 and Bias Connections1
J1 RF INPUT
20pF
20pF
20nH
J2 BIAS
100Ω
20nH
20pF
Switch
Chip
J2
20pF RF OUTPUT
MA4SW210 and Bias Connections1
J3 BIAS
J1 RF INPUT
20pF
20nH
J2 BIAS
20nH
20pF
J3
RF OUTPUT
20pF 20pF
100Ω
20nH
20pF
Switch
Chip
J2
20pF RF OUTPUT
MA4SW310 and Bias Connections1
J1 RF INPUT
20pF
J4 BIAS
20nH J2 BIAS
20nH
20pF
J4
RF OUTPUT
20pF
20pF
100Ω
20nH
20pF
20pF
J2
RF OUTPUT
J3 BIAS
20nH
20pF
20pF
J3
RF OUTPUT
Notes:
1. RLC values are for a typical operating frequency of 2 - 18 GHz
and Bias Current of ± 20mA per diode.