408-4366 Datasheet, PDF (5/10 Pages) Tyco Electronics – 626 Pneumatic Crimping Heads
Pneumatic Crimping Heads 662546- 1 and 1320369- 1
1
4
Wire Range
Stamped
Under Tongue 2
Crimp Inspection
ACCEPT
REJECT
4
3
COPALUM
Terminal
7
1
3
408- 4366
Wire Range
2 Stamped
Under Tongue
1
4
3
4
3
Wire Range 2
Stamped
On Side
COPALUM
Butt Splice
1
7
Wire Range 2
Stamped
On Side
1
COPALUM
1
Parallel Splice
5
6
3
1
3
1 Crimp centered on wire barrel. (Crimp may be slightly off
center but not off end of wire barrel.)
2 Wire size is within wire size range stamped on terminal or
splice and crimping head.
3 Wire is visible through inspection hole of butt splice.
Wire is flush with or extends slightly beyond end of
terminal wire barrel or parallel splice.
4 Wire range embossed on crimp matches wire size range
stamped on terminal or splice.
1 Crimp not centered on wire barrel. (Terminal or splice not
properly seated in crimping chamber.)
2 Wire size is not within wire size range stamped on terminal or
splice and crimping head.
3 Wire not fully inserted.
Wire is not visible through inspection hole of butt splice.
Wire is not flush with, or extending beyond, end of terminal wire
barrel or parallel splice. (Check for correct strip length.)
4 Excessive flash or extruded insulation. (Wrong crimping head
and terminal combination used, or damaged jaws.)
5 Wire insulation entered wire barrel (applies to stranded copper
wire only). Check for correct wire size or strip length.
6 Nicked or missing conductor strands (applies to stranded
copper wire only).
7 Wire range embossed on crimp does not match wire size
range stamped on terminal or splice.
Figure 5
Rev C
Tyco Electronics Corporation
5 of 10