English
Language : 

408-1662 Datasheet, PDF (5/8 Pages) Tyco Electronics – Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools.
Figure 9
2. Insert ground wire into ferrule. See Figure 10.
NOTE
i
On six smaller ferrules (Part No. 327192 and
323930 through 323934) slide the ground wire
insulation under ferrule skirt approximately /16
inch. On five larger ferrules (Part No. 327137
through 327141. DO NOT slide the ground wire
insulation under ferrule skirt.
408-1662
Pneumatic Tool
a.Place ferrule, with shielded wire and ground
wire attached, in lower crimp area of dies.
Push ferrule all the way into tool. See Figure 1
b.Hold ground wire and shielded wire in
position and depress take-up lever to hold
ferrule in place.
c.Simultaneously release take-up lever and
depress trigger to complete crimp. Release
trigger and remove crimped ferrule.
Figure 11
C. Ferrule Insulating Caps
1. Place insulating cap on ferrule as shown in
Figure 12.
2. Insulating caps are color coded for easy
matching with ferrule. To select correct insulating
cap, refer to Figure 1.
Hand Tool
Figure 10
a.Open tool handles all the way.
b.Place ferrule with shielded wire and ground
wire attached in lower crimp area of dies. Push
ferrule all the way into tool. See Figure 11.
c.Hold ground wire and shielded wire in
position and close handles until CERTI-CRIMP
tool ratchet releases. Open handles and
remove crimped ferrule.Pneumatic Tool
Rev A
Figure 12
5 of 8
LOC B