English
Language : 

MA03501D Datasheet, PDF (3/7 Pages) Tyco Electronics – X-Band Gain/Phase Control MMIC 8.0 -11.0 GHz
X-Band Serial Input Gain/Phase Control MMIC
Recommended Operating Conditions
Characteristic
Drain Voltage
Gate Voltage
Digital Power Supply Voltage
Input Logic High Voltage
Input Logic Low Voltage
Clock Frequency
Junction Temperature
MMIC Base Temperature
Symbol
Min
VDD
4.0
VGG
-4.5
VEE
-4.2
VIH
3.0
VIL
0.0
FCLK
TJ
TB
2. Maximum MMIC Base Temperature = 150°C— 31.8°C/W * VDD * IDQ
RO-P-DS-3004 - - 3/7
MA03501D
Typ
Max
Unit
5.0
6.0
V
-4.0
-3.5
V
-4.0
-3.8
V
3.5
5.0
V
0.0
0.4
V
20
MHz
150
ºC
Note 2
ºC
Operating Instructions
This device is static sensitive. Please handle
with care. To operate the device, follow these
steps.
1. Apply VGG = -4 V, VEE = -4V, VDD= 0 V.
2. Ramp VDD to desired voltage, typically 5 V.
3. Adjust VGG to set IDQ, (approximately @ –4V).
4. Set RF input.
5. Power down in reverse. Turn gate voltage off
last.
Specifications subject to change without notice.
Customer Service: Tel. (888)563-3949
Email: macom_adbu_ics@tycoelectronics.com
„ North America: Tel. (800) 366-2266
„ Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
„ Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product informaVti1o.n00.