408-4218 Datasheet, PDF (3/5 Pages) Tyco Electronics – PRO–CRIMPER III Hand Crimping Tool Assembly
PRO-CRIMPER III Hand Crimping Tool Assembly 318450-1
408-4218
Center Contact Crimp
Center Contact
Flange Against
Edge of Die
Anvil Die
Stripped
Cable
Figure 3
3. Allow the handles to open fully, and remove the
crimped center contact from the die assembly.
4.2. Ferrule (Figure 4)
1. Flare the cable braid and insert the crimped
center contact into the connector body until the
cable dielectric is against the dielectric inside the
connector body. The flared braid will then fit over
the support sleeve of the connector body.
2. Slide the ferrule forward over the braid until the
ferrule is against the connector body.
3. Place the ferrule in the ferrule crimping chamber
on the anvil die so that the shoulder of the
connector body is against the edge of the die.
4. Holding the assembly in place, close the tool
handles until the ratchet releases.
5. Allow the handles to open fully, and remove the
crimped assembly from the die assembly.
CAUTION
!
Damaged contacts must not be used. If a contact
is damaged, it must be replaced with a new one.
5. INSPECTION
5.1. Visual Inspection
The crimping dies should be inspected on a regular
basis to ensure that they have not become worn or
damaged. Inspect the crimping chambers for
flattened, chipped, worn, or broken areas. If damage
or abnormal wear is evident, the tool must be
replaced. See Section 8, DIE REPLACEMENT.
5.2. Gaging the Crimping Chamber
This inspection requires the use of a plug gage
conforming to the diameters in Figure 5. Tyco
Electronics does not manufacture or market these
gages. To gage the crimping chamber, proceed as
follows:
1. Close the jaws until the dies have bottomed,
then HOLD the frame handles in this position. Do
NOT force the dies beyond initial contact.
Ferrule Crimp
Ferrule
Cross-Sectional
View
Anvil Die
Rev B
Figure 4
Connector Shoulder
Against Edge of Die
Tyco Electronics Corporation
Anvil Die
3 of 5