Installation and Removal of Power Tap Assemblies
408-10260
CAUTION
!
If tap is soldered to pc board, remove solder
using standard de-soldering methods.
2. Remove the tap board assembly covering the
power tap.
3. Position the extraction tool over the power tap to
be removed.
4. Holding the tool firmly over the power bug,
slowly turn the knob assembly clockwise to engage
the tool threads with the threads of the power tap
load beam.
5. Continue turning the knob until the tool lifts the
power tap from the pc board.
6. Remove extraction tool from power tap by
turning tool knob counter–clockwise until threads
disengage.
6. RECOMMENDED EXTRACTION TOOL
CONFIGURATION
Refer to Figure 7 for dimensions for a recommended
extraction tool for the removal of Power Tap
Assemblies.
38.1 [1.50]
Turn Knob
Clockwise
Customer Supplied
Tool
10.50 [.413] for 6- and
10-Position Power Tap
and 15.40 [.606] for
Straddle Mount Power Tap
63.5 [2.50]
Threaded Shaft
Yoke
(See Figure 7)
20.32 [.800]
Power Tap
(Ref)
PC Board (Ref)
Figure 6
Figure 7
7. REPLACEMENT AND REPAIR
CAUTION
!
The components of the tap assembly are not
repairable. Discard and replace any defective or
damaged components. DO NOT re-use a tap
assembly after it has been removed from the pc
board.
8. REVISION SUMMARY
S Initial release of document