English
Language : 

408-10260 Datasheet, PDF (2/3 Pages) Tyco Electronics – Insulated tap assemblies include a housing for protection from other components on the pc board.
Installation and Removal of Power Tap Assemblies
408-10260
Locating Block (6- and 10-Position)
18.29 [.720]
7.40 [.291]
10.50 [.413]
Support Block
16.50
[.65]
19.05 [.750]
15.88 +0.25
[.625+.010]
9.53 [.375]
3.18 [.125] Typ
21.40
[.843]
34.9+0.25
[1.375+.010]
3.18 [.125]
Figure 2
3.18 [.125]
Locating Block (10-Position Straddle Mount)
18.29 [.720]
7.40 [.291]
4. INSTALLATION
4.1. Seating Tap onto PC Board
1. Partially insert the contacts of the tap into the
appropriate holes in the pc board.
2. Center the tap under the locating block as
shown in Figure 4. Actuate the power unit to seat
the tap onto the pc board. If desired, solder the tap
to the pc board following locally approved soldering
guidelines.
3. Inspect the mounted tap according to Figure 5.
3.18 [.125] Ref
Seating Tap
Power
Unit
Locating
Block
Tap
Support Block
0.64 [.025] Ref
Figure 4
Inspecting Mounted Tap
1
15.40 [.606]
19.05 [.750]
13.40 [.528]
24.0 [.945]
3.0
[.118]
Support Block
44.0 [1.732]
9.0 [.354]
34.9+0.25
[1.375+.010]
3.18 [.125]
Figure 3
3.18 [.125]
2
3
1
0.00-0.20 [.000-.008] Standoffs Seated on PC Board
2
Standoffs Are Not Deformed
3
Contacts Are Straight
Figure 5
5. REMOVING TAP ASSEMBLY (Figure 6)
1. DISCONNECT the tap assembly from the power
supply. Remove the cover (if applicable), screw,
and washer.
2 of 3
Tyco Electronics Corporation
Rev A