3-644466-2 Datasheet, PDF (3/84 Pages) Tyco Electronics – MTA, CST-100 II, SL-156 and AMP Economy Power | |||
|
◁ |
MTA, CST-100 II, SL-156 and
AMP Economy Power (EP) Connectors
Table of Contents (Continued)
Crimp
SL-156
Crimp
AMP EP Connectors
Need more information?
Call Technical Support at the
numbers listed below.
Technical Support is staffed
with specialists well versed
in Tyco Electronics products.
They can provide you with:
I Technical support
I Catalogs
I Technical Documents
I Product Samples
I Authorized Distributor
Locations
MTA-156 Card Edge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56, 57
Connectors â UL94V-0
Closed End with and without Mounting Ears . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Feed-Thru with and without Mounting Ears . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
SL-156 Crimp Connectors and Headers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58-62
Wire-to-Board Mateability Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Wire-to-Board Crimp Contacts and Keying Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Wire-to-Board Housings â UL94V-0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Housings with Through Board Latch â UL94V-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Housings and Contacts for Large Insulation Diameter (LID) Wire . . . . . . . . . . . . . . . . . .62
AMP Economy Power (EP) Connector System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63-69
.156 [3.96] Centerline Connectors
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Crimp Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Plug Housings, Low-Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Low-Profile Headers â Straight and Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . .65
Low-Profile Headers, High Temp. â Straight and Right-Angle Posts . . . . . . . . . . . . . . .66
.200 [5.08] Centerline Connectors
Plug Housings and Straight and Right-Angle Post Headers . . . . . . . . . . . . . . . . . . . . . .67
.312 [7.92] Centerline Connectors
Low-Profile Headers â Straight Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Single Connectors
1-Position Plug Housing and High-Profile Header â Straight Post . . . . . . . . . . . . . . . . .69
MTA Wire Selection and Ribbon Cable Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
IDC Ribbon Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71-74
MTA Wire Termination Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
MTA Application Tooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76-79
Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80-82
Global Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Connector Selection Guide
Product Name
Center-
line
Contact
Termin-
ation
Wire-to-
Wire
Option
No. of
Positions
Wire Wire
Size Insulation
(AWG) Dia. Max.
Current
Rating
(A)**
Voltage
Rating
Max. (VAC)
Operating
Temp.
Range (°C)
UL
Flammability
Replace-
ment
Contacts
Approvals
.050" Centerline
MTA-50 IDC Connector
Kits and Headers
.050
1.27
IDC Planned 2â28
30â26
.039*
0.99
1
30 â55 to +105 V-0 & V-2 No
R
R
.100" Centerline
MTA-100 Connectors
and Headers
.100
2.54
IDC
Yes
2â28
28â22
.060*
1.52
5
250 â55 to +105 V-0 & V-2 Yes
R
R
CST-100 II Contacts
and Housings
.100
.065
2.54 Crimp Planned 2â28 26â22 1.65
4
250 â55 to +105 V-0
Yes
R
R
.156" Centerline
MTA-156 Connectors
and Headers
.156
3.96
IDC
Yes
2â24
26â18
.095*
2.41
7
600 â55 to +105 V-0 & V-2 Yes
R
R
Quad Connectors
.156
.095*
3.96 IDC
No
2â12 22â18 2.41
12.5
600 â55 to +105 V-0
Yes
R
R
SL-156 Contacts
and Housings
.156
1â24; 2â10
.105
3.96 Crimp
No w/ through 24â18
board latch
2.67
10
250 â25 to +105 V-0
Yes
R
R
SL-156 Large Ins. Dia. (LID)
Contacts and Housings
.156
3.96
Crimp
No
.112
2â24 24â16 2.84
10
250 â25 to +105 V-0
Yes
R
R
.156", .200" and .312" Centerlines
.156
3.96 Crimp No
1â12
22â18
.118 8 (1 pos.)
3.00 7.5 (2â12 Pos.)
250
â25 to +105
V-0
Yes
R
R
AMP Economy Power
(EP) Connector System
.200
5.08
Crimp
No
2â12
22â18
.118
3.00
7.5 (2â12 Pos.)
250
â25 to +105
V-0
Yes
R
R
.312
.118
7.92 Crimp No
2â5 22â18 3.00 7.5 (2â5 Pos.) 250 â25 to +105 V-0
Yes
R
R
** When terminated one position at a time.
** Current Rating is application dependent.
3
Catalog 82056
Revised 6-08
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.
USA: 1-800-522-6752
Canada: 1-905-470-4425
Mexico: 52-55-1106-0800
C. America: 57-1-254-4444
South America: 55-11-2103-6000
Hong Kong: 852-2735-1628
Japan: 81-44-844-8013
UK: 44-208-420-8341
|
▷ |