English
Language : 

2-1419106-2 Datasheet, PDF (1/8 Pages) Tyco Electronics – KUP Enclosed Relay
Features
• AC coils: 6-240VAC, 50/60 Hz. DC: 6-110VDC.
• Contact arrangement up to 4PDT.
• Wide selection of termination and mounting styles.
• PC terminals available.
• Push to test button and indicator lamps.
• KUEP incorporates a blow out magnet for high voltage DC switching.
• KUIP/KUGP are VDE approved.
• Complete line of sockets and DIN rail.
• Class B coil insulation.
Contact Data @ 25°C
Arrangements: See respective ordering information table.
Materials: Fine silver (5 amp) silver-cadmium oxide (10 amp).
Gold flash available as standard.
Gold diffused and gold alloy on special order.
Expected Mechanical Life:
Contact Ratings
Material Arrangement
UL/CSA Ratings
Expected
Life
Fine
All
Silver
Silver-
Cadmium
Oxide
1-2 Pole
KUP
KUIP
KUGP
KUEP
All KUMP
KUMP
3 Pole
KUP
KUIP
4 Pole
KUEP
SPST-NO
KUEP
2PST-NO
KUEP
2PDT
(All other AC ratings apply KUEP.)
5 amps @ 28VDC or 240VAC
80% PF, 2.5 amp tungsten
@120VAC, 1/2 amp @ 120VDC.
1/6 HP @120VAC, 1/3 HP @
240VAC, 5 FLA, 15 LRA @
250VAC (FLA covered by
30,000 operations).
10 amps @ 28VDC or 240VAC,
80% PF, 5 amp tungsten @
120VAC, 3A 600VAC, 1/2 amp
@ 120VDC.
1/3 HP @ 120VAC, 1/2 HP @
240, 480, and 600VAC, 10 FLA
30 LRA @ 120VAC, 5 FLA,
15 LRA @ 250VAC.(FLA ratings
covered by 30,000 operations)
15 amp @ 277VAC, 80% PF
KUM KUMP
10 amp @ 28VDC or 120VAC,
80% PF, 6 2/3 amp @ 240VAC,
80% PF
10 amp per pole not to exceed
30 amp total @ 28VDC, 120VAC,
80% PF, 6 2/3 amp @ 240VAC,
80% PF
100,000
100,000
100,000
100,000
100,000
10 amp @ 150VDC
5 amp @ 150VDC
3 amp @ 150VDC
100,000
Initial Dielectric Strength
Between Open Contacts: 1,200V rms; KUGP, 3,500V rms.
Between Adjacent Contacts: 2,200V rms.
Between Contacts and Coil: 2,200V rms; KUGP, KUIP, 3,750V rms.
KU series
KUP Enclosed Relay
KUIP VDE 8mm Coil to Contacts
KUGP VDE 8mm 3mm Gap Coil to Contacts
KUEP 10 Amp 150VDC Load Switching
KUMP 15 Amp 277VAC
File E22575
File LR15734
0435 Registration 1792 (KUIP)
0435 Registration 1792 (KUGP)
License 81.12102.01
Coil Data @ 25°C
Voltage: 6 to 110VDC and 6 to 240VAC.
Nominal Coil Power:
DC Coils: 1.2 Watts - KUP, KUIP, KUMP, 1 - 3 pole; KUEP, 1 pole.
DC Coils: 1.8 Watts - KUP, 4 pole; KUEP, 2 pole; KUGP.
AC Coils: 2.0VA - KUP, KUIP, 1 - 2 pole; KUEP, 1 pole.
AC Coils: 2.7VA - KUP, KUIP, 3 pole; KUEP, 2 pole; KUGP, KUMP.
Coil Data
DC Volts
Nominal
5
6
12
24
48
110
AC Volts
Nominal
6
12
24
120
240
1.2 Watt
1.8 Watt
DC Ohms ± 10% Nom. I ma DC Ohms ± 10% Nom. I ma
21
238
14
360
32.1
187
20
300
120
100
80
150
472
51
320
75
1,800
26.7
1,260
38
10,000
11
6,720
16
2VA
2.7VA
DC Ohms ± 15% Nom. I ma DC Ohms ± 15% Nom. I ma
6
24
85
2,250
9,110
335
4.2
460
168
18
230
84
72
115
17.5
1,700
24
8.75
7,200
12
Operate Data @ 25°C
Must Operate Voltage:
DC Coils: 75% of nominal voltage or less.
AC Coils: 85% of nominal voltage or less.
Operating Time (Excluding Bounce):
15 milliseconds, typical, at nominal voltage.
Release Time (Excluding Bounce):
10 milliseconds, typical, at nominal voltage.
Environmental Data
Temperature Range:
Operating: Enclosed Relays: -45°C to maximum listed in table below.
Open Relays: Add 15°C to maximum listed.
Max C° +45°C
KUP
KUIP
AC
3-4 pole
KUGP
KUEP
KUMP
AC
2 pole
AC
3 pole
+50°C
DC
4 pole
DC
2 pole
+55°C +70°C
AC
1-2 pole
AC
1 pole
AC
1-2 pole
DC
1-3 pole
AC
3 pole
AC
2 pole
DC
1 pole
DC
1-3 pole
+75°C
DC
2 pole
+80°C
AC
1-2 pole
+95°C
DC
1-3 pole